Sampling the Hydraulic Fluid

Model 505.20 - 505.30 SilentFlo™ HPU

Maintenance

65

6. If there still is any uncertainty regarding fluid quality, obtain another sample

of the fluid and have it analyzed. The fluid tests should include chemical
analysis, particle count, and viscosity checks. Most oil companies have
facilities for performing these tests, or consult MTS Systems Corporation.

7. Close the needle valve and remove the hose and valve assembly. Open the

needle valve.

Appearance of Hydraulic Fluid Sample

Fluid Properties

Problem

What to Do

Dark colored fluid

Indicates chemical breakdown or
the hydraulic fluid has been allowed
to rise above the maximum
recommended temperature (severe
overheating)

Analyze the fluid and replace as
required by the analysis.

If the cause was overheating, flush the
entire system to remove varnish or
residue. Consult your MTS Field
Service Engineer to determine if
changes or adjustments to your
hydraulic system are required.

Burnt odor

Indicates chemical breakdown or
the hydraulic fluid has been allowed
to rise above the maximum
recommended temperature (severe
overheating)

Analyze the fluid and replace as
required by the analysis.

If the cause was overheating, flush the
entire system to remove varnish or
residue. Consult your MTS Field
Service Engineer to determine if
changes or adjustments to your
hydraulic system are required.

Opaque fluid

Indicates chemical breakdown

Replace the fluid

Milky appearance

Indicates water is present in the
fluid

Check the heat exchanger for damage.

Look for other water sources if the
water does not appear to be coming
from the heat exchanger.

Identify and correct the source of the
water leakage and replace the fluid if
necessary.

Sediment at the bottom of
the sample container (after
sample has stood
overnight)

Indicates collapsed, ruptured, or
clogged filter(s)

Analyze the fluid and replace all filter
elements.

Clean the fluid or replace it as required
by the analysis.