531-8661-00 MMF Multi-Serial Interface Page 4 of 12
Switch 3
“Dumb Mode” any open character based on the number of pulses within that ASCII character will open the cash
drawer.
The above SW3 Functions only apply when the controller is set to “Dumb Mode” (SW3-1 = OFF)
“Smart Mode” open character and RS-232 settings are pre-selected.
The above SW3 Functions only apply when the controller is set to "Smart Mode" (SW3-1 = ON)
Parity / 7 Data Bits Note: When the number of data bits is set to 7 (SW2-8 = OFF) parity must
be Enabled
(SW3-7 = ON). Setting the number of data bits to 7 while parity is disabled will result in an invalid mode. If the
controller is set to this mode, LED #1 (green) and LED #2 (red) will blink to indicate the invalid condition.
P
O
S
SW3 - "Dumb Mode"
FUNCTION
1
Smart Mode (ON) / Dumb Mode (OFF) Select
2
Drawer Status Polarity (OFF = Norm / ON = Invert)
3
Pulse Count 0
4
Pulse Count 1
5
Reserved
6
Reserved
7
Reserved
8
Reserved
PULSE COUNT SELECT SW3
Pos 4
Pos 3
Number
P-Cnt 1
P-Cnt 0 of Pulses
OFF
ON
4 Pulses
OFF
OFF
4 Pulses
ON
ON
3 Pulses
ON
OFF
2 Pulses
P
O
S
SW3 - "Smart Mode"
FUNCTION
2
Drawer Status Polarity (OFF=Norm / ON=Invert)
3
Baud Rate
4
Baud Rate
5
Baud Rate
6
Parity Type (OFF = Even / ON = Odd)
7
Parity Enable (ON = Parity Enabled)
8
Number of Data Bits (OFF = 7 Bits, ON = 8 Bits)
BAUD RATE SELECT
Pos
5
Pos
4
Pos
3
Baud Rate
OFF
OFF
OFF
300
OFF
OFF
ON
600
OFF
ON
OFF
1200
OFF
ON
ON
2400
ON
OFF
OFF
4800
ON
OFF
ON
9600
ON
ON
OFF
19200