d

esign

/ i

nsTallaTion

C

onsideraTions

(

ConT

)

Proper design and installation of vapor barriers and ventilation systems are important to prevent condensation and the resulting

problems of moisture damage and loss of insulation efficiency.

Condensation occurs when moisture laden air comes in contact with a surface temperature equal to or below the dew point

of the air. This phenomenon creates problems that are not unique with metal roofing; these problems are common to all

types of construction.

The underside of the metal roof on a typical Architectural building should be protected from condensation by installing

panels directly over a minimum 30 lb moisture barrier and uniform solid substrate. This reduces airspace and the potential of

condensation forming on the underside of the panels.

VENTILATION

Typical metal building (no attic)

Vent

Vent at wall

Vent at

eave

Building with attic or retrofitted

Vent

Insulation

PANEL APPLICATIONS

The following chart highlights UL 580 Class 90 for clip installation on the selected applications (see Fastener Selection Guide

page PGI-12-14 for other fasteners available). For more information on UL Construction numbers, refer to UL Roofing Materials

and System Directories.

* Length of Deck Screw will vary depending on the total thickness of the rigid insulation and metal decking.

** Based on UL-580. Subject to project loading, closer clip (fastener) spacing may be required. Contact your local Metal

Sales branch representative for more information (see pages 2 and 3).

1. For 1" Mini-Batten over

5

/

8

" plywood deck only.

BEARING PLATE

NUMBER

REQUIRED

TYPE OF FASTENER

APPLICATION

INSTALLATION

REQUIREMENTS

CLIP

SPACING

PANEL TYPE

#10-12 x 1" PANCAKE WOODSCREW

1 FASTENER

24 GAUGE

PANEL

2'-0" O.C.**

CLIPS OVER

5

/

8

" WOOD DECK

CONST. #430

UL-90

1 FASTENER

*#14-13 x L DECK SCREWS

#10-12 x 1" PANCAKE WOODSCREW

1 FASTENER

24 GAUGE

PANEL

24 GAUGE

PANEL

2'-0" O.C.**

2'-0" O.C.**

CLIP OVER RIGID

INSULATION /

METAL DECK

CONST. #397A

CLIPS OVER

5

/

8

" WOOD DECK

CONST. #398

UL-90

UL-90

1 FASTENER

*#14-13 x L DECK SCREWS

24 GAUGE

PANEL

2'-0" O.C.**

CLIP OVER RIGID

INSULATION /

METAL DECK

CONST. #398A

UL-90

MINI-BATTEN

1

MAXI-BATTEN

This manual is related to the following products: