Mini/maxi-batten, Ul 263 f – Metal Sales Mini-Batten User Manual
Page 7
MINI/MAXI-BATTEN
PMB-7
© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11
800.406.7387 (Corporate Office) • www.metalsales.us.com
Ul 263 f
ire
r
esisTanCe
r
aTings
METAL SALES MANUFACTURING CORPORATION
R9697
Mechanically attached metal roof panels - Type “Low Mini-Batten Panel and Cap” secured by steel
anchor clips. Anchor clips are attached to a hat shaped member* (minimum depth 1 in.) or a bearing
plate**.
For use in Design Nos. P224 , P225 , P227 , P230 , P237 , P508 , P510 , P512 , P701 , P711 , P712
, P713 , P715 , P717 , P720 , P722 , P723 , P724 , P726 , P731 , P734 , P736 , P803 , P814 , P815 ,
P818 , P819 , P821 , P823 , P824 .
*Hat shaped member to be a minimum of 16 gauge. The member will be fastened through the roof
insulation to the steel roof deck with min. No. 14 self-drilling and/or self-tapping fasteners. Spacing
to be determined by the structural loading requirements. In addition any compressible UL Classified
glass fiber blanket insulation with or without a vapor retarder facing may be used between the speci-
fied roof insulation and the metal roof panels.
**Bearing plate to be a minimum of 16 gauge. Member will be fastened through the roof insulation to
the steel deck with min. No. 14 self-drilling and/or self-tapping fasteners.
See the UL Fire Resistance Directory for explanation of each design number listed above.
Metal Roof Deck Panels
Metal Sales Manufacturing Corporation has obtained fire resistance ratings for various products
conducted according to test criteria set forth by 'Underwriters Laboratories' "Standard Fire Tests
of Building Construction and Material" (ANSI/UL 263). This test procedure is identical to ASTM
E-119 and NFPA 251.
The fire resistance rating is for the total assembly and not just the external metal panel. Ratings
are expressed in hours and vary depending upon the assemblies. In general, the test criteria is to
evaluate the assembly's ability to continue to support the superimposed loads and resist the pas-
sage of flame, high temperatures, or hot gases which will ignite combustible materials. The test
assemblies are identified by an alpha-numeric design number.
For detail information on specific assemblies and hourly ratings see UL Fire Resistance Directory.
Underwriters Laboratories Inc.
®
UL
®