Periodic Error Correction (PEC) Training
(Polar Alignment and RA Drive Only)

If you wish to improve the tracking performance

on your telescope, fi rst, perform the train the drive

procedure (see page 57). Then use the Periodic

Error Correction (PEC)/Train menu option to remove

the slight perturbations from center that occur due to

the mechanical nature of a telescope. To perform this

procedure, you need to use a high-power reticle, such

as the 9mm reticle (see OPTIONAL ACCESSORIES,

page 52).

Important Note: In order for the Smart Drive

training to operate and be updated properly,

you must “park” the telescope (see PARK

SCOPE, page 41) when fi

nished with your

observing session.

PEC Train Menu Option

To perform the procedure on the RA axis, pick a bright

star in the South that has minimal movement and is

about 30° above the horizon (Note: If in the Southern

hemisphere, pick a star in the North that is about 30°

above the horizon).

Important Note: The Train option overwrites any

previous PEC data.

1. Select “PEC Train” from the Smart Drive

menu (in the “Setup: Telescope” menu) and

press ENTER.

2. Look through the reticle. Use the Arrow keys to

keep the star centered in the reticle cross-hairs.

AudioStar displays a count of the 150 positions

of the worm gear. When the count reaches 150,

one cycle is complete. A full cycle takes about

9.5 minutes.

3. Press MODE to exit.

PEC Update Menu Option

PEC Update does not overwrite the data, but updates

the training using information gathered from both

the last and the current training sessions. Press the

MODE key to exit from this option. If you wish to further

refi ne your training, select this menu again and repeat

the procedure.

PEC Erase Menu Option

Select this option to erase all PEC training data.

PEC On and Off Menu Options

Select “On” when you want the telescope to use the

training information. Select “Off” when you do not want

for the telescope to use the training information.

AudioStar #497 HANDBO

X

Appendix D:

Equatorial ( P

olar

Alignment)

64