Electrical installation – Lenze ECSEExxx User Manual
Page 99

Electrical installation
Control terminals
4
99
EDKCSEE040 DE/EN/FR 4.0
Assignment of the plug connectors
Terminal strip X6
View
Terminal
Function
Electrical data
T1
DO1
DI2
DI1
T2
D24
GND
+24
X6/+24
Low-voltage supply of control
electronics
20 ... 30 V DC, 0.5 A (max. 1 A)
for 24 V starting current:
max. 2 A for 50 ms
X6/GND
Reference potential low-voltage
supply
X6/T1
Thermostat contact 1
X6/T2
Thermostat contact 2
X6/D24
Low-voltage supply X6/DO1
(digital output 1)
18 ... 30 V DC
X6/DO1
Digital output 1
(for central controller enable
signal to connected axis
modules)
24 V DC, 0.7 A (max. 1.4 A)
short-circuit-proof
X6/DI1
Digital input 1
(for power supply enable/charge
of the DC bus)
LOW:
-3 ... +5 V;
-3 ... +1.5 mA
HIGH:
+15 ... +30 V;
+2 ... +15 mA
Input current at 24 V DC:
8 mA per input
X6/DI2
Digital input 2
(for central controller enable
signal to connected modules;
available at output X6/DO1)
Cable cross-sections and screw-tightening torques
Cable type Wire end ferrule
Cable cross-section Tightening torque
Stripping length
Flexible
Without wire end
ferrule
0.08 ... 1.5 mm
2
(AWG 28 ... 16)
0.22 ... 0.25 Nm
(1.95 ... 2.2 lb-in)
5 mm for screw
connection
9 mm for spring
connection
With insulated wire
end ferrule
0.25 ... 0.5 mm
2
(AWG 22 ... 20)
We recommend to use control cables with a cable cross-section of 0.25 mm
2
.