Troubleshooting and fault elimination
Fault messages on the keypad or in the parameter setting program Global Drive Control
l
22
EDK82EV303 EN 1.0
Remedy
Cause
Fault
PC
1)
Keypad
OH3
a
53
PTC monitoring (TRIP)
(Display when
C0119 = 1 or 4)
Motor too hot due to impermissibly
high currents or frequent and too long
acceleration processes
Check drive dimensioning
No PTC connected
Connect PTC or switch off monitoring
OH4
a
54
Controller
overtemperature
Controller too hot inside
l
Reduce controller load
l
Improve cooling
l
Check fan in the controller
OH51
203
PTC monitoring
(Display when
C0119 = 2 or 5)
Motor too hot due to impermissibly
high currents or frequent and too long
acceleration processes
Check drive dimensioning
No PTC connected
Connect PTC or switch off monitoring
OU
c
−
DC bus overvoltage
(Message or TRIP
configurable in C0310)
Mains voltage too high
Check supply voltage
OUE
a
22
Braking operation
l
Increase deceleration times
l
When operating with an external brake
resistor:
– Check dimensioning, connection and
supply cable of the brake resistor
– Increase deceleration times
Earth leakage on the motor side
Check motor supply cable and motor for
earth fault (disconnect motor from the
inverter)
Pr
a
75
Faulty parameter
transfer with the
keypad
All parameter sets are defective
Before enabling the controller, repeat the
data transfer or load the Lenze setting
Pr1
a
72
Faulty PAR1 transfer
with keypad
Parameter set 1 is defective
Pr2
a
73
Faulty PAR2 transfer
with keypad
Parameter set 2 is defective
Pr3
a
77
Faulty PAR3 transfer
with keypad
Parameter set 3 is defective
Pr4
a
78
Faulty PAR4 transfer
with keypad
Parameter set 4 is defective
Pr5
a
79
Internal fault
EEPROM is defective
Contact Lenze
PT5
a
81
Time error during
parameter set transfer
Data flow from keypad or PC
interrupted, e.g. because keypad was
disconnected during transfer
Before enabling the controller, repeat the
data transfer or load the Lenze setting.
rST
a
76
Error during auto TRIP
reset
More than 8 error messages within
10 minutes
Depends on the error message
sd5
a
85
Open circuit − analog
input 1
Current at analog input < 4 mA at
setpoint range 4 ... 20 mA
Close circuit at analog input
sd7
a
87
Open circuit − analog
input 2
1)
LECOM error number, display in Global Drive Control (GDC) parameter setting program