2 display elements and function keys, Display elements and function keys, Z y w x – Lenze 8200 vector 15kW-30kW User Manual
Page 13: Vt u s, Parameter setting
Parameter setting
Parameter setting with E82ZBC keypad
Display elements and function keys
l
13
EDK82EV303 EN 1.0
2.1.2
Display elements and function keys
z
y
w x
v
t
u
s
88888
8888
888
8
a
b
c
d
e
j g f k i h PS
m n o
p
q r
Hi
Hz
%sh
rpm
°C
Ω
m
A
V
Lo
8
0
3
1
2
4
6
5
7
E82ZBC002
Displays
Display
Meaning
Explanation
0 Status displays
d
Ready for operation
c
Pulse inhibit active
Power outputs are inhibited
b
Set current limit exceeded in motor or
generator mode
C0022 (in motor mode) or C0023 (in generator
mode)
e
Warning active
a
Fault active
1 Function bar 1
j
Setpoint selection via
yz
Not possible if password protection is active (display
= "loC")
g
Display function:
l
Display user menu, memory location 1
(C0517/1)
l
Display active parameter set
Active after every mains connection
f
Select codes
Four−digit display of the active code
5
k
Select subcodes
Three−digit display of the active subcode
6
i
Change parameter value of a code/subcode
Five−digit display of the actual value
7
h
Display values which have more than 5
digits
H:
higher−order digits
Display of "HI"
L:
lower−order digits
Display of"lo"
2 Function bar 2
m
Select parameter set 1 ... 4 for changing
l
Display of e.g. PS 2 (4)
l
The parameter sets can only be activated via
digital signals (configuration with C0410)
n
Select node of the system bus (CAN)
The selected node can be parameterised from the
current drive
r = Function is active
o
Select menu
The user menu is active after every mains
switching
user
List of the codes in the user menu (C0517)
all
List of all codes
funCi
Only specific codes for bus function
modules, e.g. INTERBUS, PROFIBUS−DP,
LECOM-B, ...