Technical data – Lenze E94AZMS0314 User Manual
Page 39

Technical data
General data and operating conditions
EDK94AZMS DE/EN/FR/ES/IT 8.0
39
l
H1_Daten−Abmess E94AZMS GG 1−3_en
Environmental conditions
Climate
Storage
IEC/EN 60721−3−1
1K3 (−25 ... +60 °C)
Transport
IEC/EN 60721−3−2
2K3 (−25 ... +70 °C)
Operation
IEC/EN 60721−3−3
3K3 (−10 ... +55 °C)
Current derating at +45 ... +55 °C:
Device size 1 ... 7: 2.5 %/°C
Device size 8S ... 10: 1 %/°C
Site altitude
0 ... 4000 m amsl
1000 ... 4000 m amsl: current derating of 5 %/1000 m
Pollution
EN 61800−5−1
Degree of pollution 2
Vibration resistance
(9.81 m/s
2
= 1 g)
Transport
IEC/EN 60721−3−2
2M2
EN 61800−2
2 ... 9 Hz: amplitude 3.5 mm
10 ... 200 Hz: acceleration resistant up to 10 m/s
2
200 ... 500 Hz: acceleration resistant up to 15 m/s
2
Operation
Germanischer
Lloyd
5 ... 13.2 Hz: amplitude ±1 mm
13.2 ... 100 Hz: acceleration resistant up to 0.7 g
IEC/EN 60068−2−6
10 ... 57 Hz: amplitude 0.075 mm
57 ... 150 Hz: acceleration resistant up to 1 g
Mounting conditions
Mounting place
In the control cabinet
Mounting position
Vertically
Free space
The required free space results from the mounting
position and the specifications of the standard device.
Mounting position
Standard
Footprint mounting; standard device is screwed on
the filter
Variant
Side−by−side mounting; filter is directly screwed to the
left of the standard device (
^
Mechanical
installation)