Technical data, General data and operating conditions – Lenze E94APNE User Manual
Page 37
Technical data
General data and operating conditions
l
37
EDK94PNE36 DE/EN/FR/ES/IT 3.1
Connection conditions for DC power supply module
AC mains operation
Direct connection
DC−bus operation
Direct connection of axis modules via terminals or busbar
system
More information can be found in the Hardware Manual,
chapter "DC−bus operation".
Environmental conditions
Climate
Storage
IEC/EN 60721−3−1
1K3 (−25 ... +60 °C)
Transport
IEC/EN 60721−3−2
2K3 (−25 ... +70 °C)
Operation
IEC/EN 60721−3−3
3K3 (−10 ... +55 °C)
Current derating at +45 ... +55 °C: 2.5 %/°C
Site altitude
0 ... 4000 m amsl
1000 ... 4000 m amsl: current derating of 5 %/1000 m
Pollution
EN 61800−5−1
Pollution degree 2
Vibration resistance
(9.81 m/s
2
= 1 g)
Transport
IEC/EN 60721−3−2
2M2
EN 61800−2
2 ... 9 Hz: amplitude 3.5 mm
10 ... 200 Hz: acceleration resistant up to 10 m/s
2
200 ... 500 Hz: acceleration resistant up to 15 m/s
2
Operation
Germanischer Lloyd
5 ... 13.2 Hz: amplitude ±1 mm
13.2 ... 100 Hz: acceleration resistant up to 0.7 g
IEC/EN 60068−2−6
10 ... 57 Hz: amplitude 0.075 mm
57 ... 150 Hz: acceleration resistant up to 10 m/s
2