Overview – Lenze E94APNE User Manual
Page 26
l
26
EDK94PNE36 DE/EN/FR/ES/IT 3.1
Overview
Standard device
0
Pos.
Description
X11
24 V supply
X12
4 digital outputs
1 digital input
2
Nameplate, retractable
3
Setting of mains voltage/brake chopper threshold
4
Upper cap
The LED display enables fast indication of several operating states.
LED
Labelling
Colour
Description
−
−
−
OVERHEAT
Red
Overtemperature
MAINS
Green
Mains voltage OK
BRCHOP FAIL
Red
Short circuit on brake chopper
24 V
Green
24 V supply voltage OK
SSP94LED21
BRCHOP ON
Yellow
Brake chopper active
Pos.
Symbol
Description
5
{
Long discharge time: All power terminals carry hazardous voltages for at
least 3 minutes after mains disconnection!
}
High discharge current: Fixed installation and PE connection to EN 61800−5−1
required!
'
Electrostatic sensitive devices: Before working on the device, personnel must
ensure that they are free of electrostatic charge!
Installation backplane
1
Pos.
Description
X111
Mains (supply from above, e.g. from top filters)
DC−bus voltage (compatible with 9300 series)
X112
Mains (supply from below, e.g. from built−on filter)
External brake resistor
X109
DC−bus busbar +
Direct connection of
9400 axis modules,
device sizes 1 ... 3
X110
DC busbar −
6
EMC shield clamp
© 2009 Lenze Automation GmbH, Hans−Lenze−Str. 1, D−31855 Aerzen
No part of this documentation may be reproduced or made accessible to third parties without written consent by Lenze Automa-
tion GmbH.
All information given in this documentation has been selected carefully and complies with the hardware and software described.
Nevertheless, discrepancies cannot be ruled out. We do not take any responsibility or liability for any damage that may occur. Ne-
cessary corrections will be included in subsequent editions.