beautypg.com

Commissioning, 4commissioning, 2 electronic programming module (epm) – Lenze SMD 0-25kW-4-0kW User Manual

Page 14: 1 parameter setting

background image

12

Lenze 13435747 EDBSX03 v17

EN, DE, FR, IT, ES

Commissioning

4.2

Electronic programming module (EPM)

The EPM contains the controller’s memory. Whenever parameter settings are changed,

the values are stored in the EPM. It can be removed, but must be installed for the

controller to operate (a missing EPM will trigger an F1 fault). The controller ships with

protective tape over the EPM that can be removed after installation.

An optional EPM Programmer (EEPM1RA) is available that allows: the controller to be programmed

without power; OEM settings to be default settings; fast copying of EPMs when multiple controllers require

identical settings. It can also store up to 60 custom parameter files for even faster controller programming.

Tmd007

4

Commissioning

4.1

Parameter setting

Status/fault messages

Change parameters

smd004

NOTE

If the password function is enabled, the password must be entered into C00 to

access the parameters. C00 will not appear unless the password function is enabled.

Refer to C94.