Technical data, Electrical data, Output data – Lenze 9400 Mounting Instructions User Manual
Page 56: Rated data for internal brake chopper
![background image](/manuals/565655/56/background.png)
Technical data
Electrical data
l
56
EDK94ASH24 DE/EN/FR/ES/IT 4.1
Output data
Voltage
Frequency
1)
Current [A]
Number of
phases
Type
[V]
[Hz]
max. +45 °C
max. +55 °C
E94ASxE0024
0 − 230/400/500
0 − 599
1.5/1.5/1.3
1.1/1.1/1.0
3
E94ASxE0034
0 − 230/400/500
0 − 599
2.5/2.5/2.2
1.9/1.9/1.7
3
E94ASxE0044
0 − 230/400/500
0 − 599
4.0/4.0/3.5
3.0/3.0/2.6
3
E94ASxE0074
0 − 230/400/500
0 − 599
7.0/7.0/6.1
5.3/5.3/4.6
3
E94ASxE0134
0 − 230/400/500
0 − 599
13.0/13.0/11.4
9.8/9.8/8.6
3
E94ASxE0174
0 − 230/400/500
0 − 599
16.5/16.5/14.4
12.4/12.4/10.8
3
E94ASxE0244
0 − 230/400/500
0 − 599
23.5/23.5/20.6
17.6/17.6/15.5
3
Temperature in the control cabinet
Power loss P
V
[W]
Type
when operating with rated output current I
aN
when controller is inhibited
E94ASxE0024
110
40
E94ASxE0034
130
E94ASxE0044
160
E94ASxE0074
210
E94ASxE0134
320
E94ASxE0174
380
E94ASxE0244
500
Rated data for internal brake chopper
Switching
threshold
(adjustable)
Minimum
brake resistor
Peak current
Peak braking
power
Continuous
current
RMS
Continuous
braking
power
Type
U
BRmax
[V]
R
Bmin
[
W]
I
BRmax
[A]
P
BRmax
[kW]
I
BRd
[A]
P
Bd
[kW]
E94ASxE0024
390/790
47/82
8.3/8.8
3.2/6.4
3.7/3.9
0.6/1.3
E94ASxE0034
390/790
47/82
8.3/8.8
3.2/6.4
3.7/3.9
0.6/1.3
E94ASxE0044
390/790
27/47
14.4/15.4
5.6/11.2
5.9/6.3
1.0/1.9
E94ASxE0074
390/790
27/47
14.4/15.4
5.6/11.2
6.9/7.4
1.3/2.6
E94ASxE0134
390/790
18/27
21.7/26.9
8.5/19.5
10.6/13.2
2.0/4.7
E94ASxE0174
390/790
9/18
43.3/40.3
16.9/29.2
20.3/18.9
3.7/6.4
E94ASxE0244
390/790
9/18
43.3/40.3
16.9/29.2
24.5/22.8
5.4/9.3
Assignment of installation backplane ˘ standard device
Axis controller
type
Installation
backplane type
Busbar mounting set / fuse
1)
Device size
E94ASxE0024
E94AZPS0034
E94AZJA003/ EFSAR0016ARHN
I
E94ASxE0034
E94ASxE0044
E94AZPS0074
E94AZJA007/ EFSAR0040ARHN
II
E94ASxE0074
E94ASxE0134
E94AZPS0244
E94AZJA024/ EFSAR0100ARHN
(tightening torque: 3.4 Nm
(30lb−in))
III
E94ASxE0174
E94ASxE0244
1)
The busbar mounting set with fuse is available as an accessory. It is required when Single Drives are operated in
DC−bus connection via the DC busbar.