Bunn TNTF-3 User Manual

Page 9

background image

Page 9

TROUBLESHOOTING (cont.)

PROBLEM

PROBABLE CAUSE

REMEDY

Brew cycle(s) will not start (cont.)

Brew water is not hot

Dilution (Iced Tea) cycle will not
start

6. Brew Timer

A) Iced Tea

B) Hot Tea

7. Brew Solenoid Valve

A) Iced Tea

B) Hot Tea

8. Internal Flow control (.222 GPM)
(Hot Tea Only)

1. Limit Thermostat
CAUTION - Do not eliminate or by-
pass limit thermostat. Use only
BOM replacement part
#29329.1000

2. Thermal Fuse
CAUTION - Do not eleminate or by-
pass thermal fuse.

3. Control Thermostat

4. Tank Heater

1. ICED/OFF/HOT Switch

Refer to

Service

- Brew Timer (Iced

Tea) for testing procedures. See
page 20 or 21

Refer to

Service

- Brew Timer (Hot

Tea) for testing procedures. See
page 17 or 18

Refer to

Service

- Brew Solenoid

Valve (Iced Tea) for testing proce-
dures. See page 16

Refer to

Service

- Brew Solenoid

Valve (Hot Tea) for testing proce-
dures. See page 15

(A) Direction of flow arrow must be
pointing towards brewer.

(B) Remove the flow control and
check for obstructions. Clear or re-
place.

Refer to

Service

- Limit Thermostat

for testing procedures. See page 25

Refer to

Service

- Thermal fuse for

testing procedures. See page 29

Refer to

Service

- Control Thermo-

stat for testing procedures. See
page 23

Refer to

Service

- Tank Heater for

testing procedures. See page 28

Refer to

Service

- ICED/OFF/HOT

Switch for testing procedures. See
page 26

28201 081500