beautypg.com

Wiring diagram – Bunn TNTF-3 User Manual

Page 23

background image

Page 23

BU

NN

BUNN

OFF

OFF

HI

HI

Location:

The control thermostat is located inside hood on

the right side just behind the iced tea brew timer.

Test Procedures:
1. Disconnect the brewer from the power source.
2. With a voltmeter, check the voltage across the blue

wire on the control thermostat and the white wire
on the tank heater for 120 volt two wire models or
red wire on the tank heater for 120/208 volt three
wire models. Connect the brewer to the power
source. The indication must be:
a) 120 volts ac for two wire 120 volt models.
b) 208 volts ac for three wire 120/208 volt mod-
els.

3. Disconnect the brewer from the power source.

If voltage is present as described, proceed to #4.
If voltage is not present as described, refer to the

Wiring Diagram

and check the brewer wiring harness.

4. Locate the black wire on the control thermostat.
5. Gently remove the capillary bulb and grommet

from the tank.

6. With a voltmeter, check the voltage across the

black wire of the control thermostat and the white
wire on the tank heater for 120 volt two wire mod-
els or red wire on the tank heater for 120/208 volt
three wire models when the control thermostat is
turned fully clockwise. Connect the brewer to the
power source. The indication must be:
a) 120 volts ac for two wire 120 volt models.

b) 208 volts ac for three wire 120/208 volt mod-
els

8. Disconnect the brewer from the power source.

If voltage is present as described, reinstall the capil-
lary tube into the tank to the line 4.5" above the bulb,
the control thermostat is operating properly.
If voltage is not present as described, replace the ther-
mostat.

Removal and Replacement:
1. Remove both wires from the control thermostat

terminals.

2. Remove the thermostat capillary bulb by firmly

pulling up on the capillary tube at the tank lid. This
will disengage the grommet from the tank lid.

3. Remove the #8-32 screw holding the control ther-

mostat to its bracket.

4. Slide the grommet to the line 4.5" above the bulb

on the new capillary tube.

5. Insert the capillary bulb through the hole in the

tank lid and press the grommet firmly and evenly
so that the groove in the grommet fits into the
tank lid.

6. Carefully bend the capillary tube so that the tube

and bulb inside the tank are in a vertical position.

NOTE – The capillary tube must be clear of any elec-
trical termination and not kinked.

7. Fasten the new control thermostat to its bracket.
8. Refer to Fig. 15 when reconnecting the wires.
9. Adjust the control thermostat as required.

FIG. 15 CONTROL THERMOSTAT TERMINALS

P1390

BLK to Tank Heater or
Thermal Fuse on Models
W/Faucet

BLU to Limit Thermostat

P2213.60

FIG. 14 CONTROL THERMOSTAT

SERVICE (cont.)

CONTROL THERMOSTAT

28201 081598