TROUBLESHOOTING (cont.)

PROBLEM

Water flows into tank continuously
(ICED/OFF/HOT Switch in the "ICED
or "HOT" position)

Water flows into tank continuously
(ICED/OFF/HOT Switch in the "OFF"
position)

Beverage overflows dispenser

PROBABLE CAUSE

1. Brew Timer

A) Iced Tea

B) Hot Tea

1. Brew Solenoid Valve

A) Iced Tea

B) Hot Tea

1.Dispenser

2. Brew Timer

A) Iced Tea

B) Hot Tea

3. Brew Solenoid Valve

A) Iced Tea

B) Hot Tea

4. Dilution Solenoid Valve

REMEDY

Refer to

Service

- Brew Timer (Iced

Tea) for testing procedures. See
page 20

Refer to

Service-

Brew Timer (Hot

Tea) for testing procedures. See
page 17

Refer to Service - Brew Solenoid
Valve (Iced Tea) for testing proce-
dures. See page 16

Refer to

Service

- Brew Solenoid

Valve (Hot Tea) for testing proce-
dures. See page 15

The dispenser must be completely
empty before starting a brew cycle.

Refer to

Service -

Brew Timer (Iced

Tea) for testing procedures. See
page 20 or 21

Refer to

Service

- Brew Timer (Hot

Tea) for testing procedures. See
page 17 or 18

Remove the Iced Tea Brew Solenoid
Valve and clean any obstruction.
Rebuild or replace the valve if nec-
essary. See page 16

Remove the Hot Tea Brew Solenoid
Valve and clean any obstruction.
Rebuild or replace the valve if nec-
essary. See page 15

Refer to

Service

- Dilution Solenoid

Valve for testing procedures. See
page 24

28201 081500