beautypg.com

Fig. 27 thermal fuse therminals – Bunn TNTF-3 User Manual

Page 29

background image

Page 29

SERVICE (cont.)

THERMAL FUSE (Models W/Faucet Only)

FIG. 26 THERMAL FUSE

P2213.60

Location:

The thermal fuse is located inside the hood con-

nected to the right tank heater terminal.

Test Procedures:
1. Disconnect the brewer from the power source.
2. Disconnect the thermal fuse from the right tank

heater terminal and the black lead from the con-
trol thermostat.

3. With an ohmmeter, check for continuity across

the thermal fuse terminals.

If continuity is present as described, the thermal fuse
is operating properly.
If continuity is not present as described, replace the
thermal fuse.

Removal and Replacement:
1. Disconnect the thermal fuse from the right tank

heater terminal and the black lead from the con-
trol thermostat.

2. Remove thermal fuse and discard.
3. Connect new thermal fuse to the right tank heater

terminal and the blaclead from the control ther-
mostat

4. Refer to Fig. 27 when reconnecting wires.

BU

NN

BU

NN

OF

F

OF

F

HI

HI

FIG. 27 THERMAL FUSE THERMINALS

P1393.70

Thermal Fuse

BLK Lead from
Control Thermostat

Tank Heater
Terminals

28201 081598

This manual is related to the following products: