Koolance RP-985 User Manual
Page 6

4
5
User Manual
System Features
Alarm & Shutdown Settings
By default, the Koolance audio alarm will sound if any sensor reaches 55ºC (131ºF).
When the system alarm sounds, the appropriate LED temperature will flash in the
display and the radiator fans and pump will increase to 100% power.
To change this setting for an individual sensor, choose the desired channel with
SET, and press and hold
▼ + ▲ together for 3 seconds. The alarm temperature
will begin flashing. You may change this value from 0ºC (32ºF) up to 99ºC (210ºF).
The normal temperature reading will resume if you do not press any buttons for
4 seconds.
CAUTION: Generally, sensors report liquid temperature at the water
block, which is typically 5-10°C (9-18°F) lower than the actual heat
source. This difference must be considered if adjusting alarm/shut-
down temperatures. Activating alarm/shutdown modes at too high of
temperature may be unsafe. See “Temperature Sensor Placement” for
information on attaching sensors.
!
the ▼ or ▲ buttons to adjust pump settings, or hold down an arrow to skip to the
lowest or highest mode directly. There is no automatic mode for the pump.
Manual
Mode
Auto Mode Temperature
Range
Fan Duty
μs
Fan Power
%
Pump
Voltage
Pump
Power %
1
0 - 35ºC (32 - 95ºF)
5
20
7.68
60
2
36 - 37ºC (97 - 99ºF)
6
24
7.83
62
3
38 - 39ºC (100 - 102ºF)
7
28
8.08
64
4
40 - 41ºC (104 - 106ºF)
9
36
8.36
66
5
42 - 43ºC (108 - 109ºF)
11
44
8.7
69
6
44 - 45ºC (111 - 113ºF)
13
52
9.05
72
7
46 - 47ºC (115 - 117ºF)
16
64
9.59
76
8
48 - 49ºC (118 - 120ºF)
19
76
10.53
84
9
50 - 51ºC (122 - 124ºF)
22
88
11.33
90
10
52 - 99ºC (126 - 210ºF)
25
100
12.6
100
To reset all temperature alarms to their default (55ºC / 131ºF) setting, press and
hold the ºC/F button until “dEF” flashes in the display. NOTE: This will also reset
the fan speed mode to “auto”, and pump power to 100%.
If any sensor reaches 3ºC (5ºF) above the alarm temperature, the unit will trigger
the “ATX pass-through” wire relay. For a computer, this is equivalent to holding
in the power button for several seconds to force shut down. With default alarm
settings, this means the shutdown signal is sent if any sensor reaches 58ºC
(136ºF).
RP-1005
RP-985
Manual
Mode
Auto Mode Temperature
Range
Duty
μs
Fan Power
%
Pump
Power %
1
0 - 35ºC (32 - 95ºF)
5
20
20
2
36 - 37ºC (97 - 99ºF)
6
24
24
3
38 - 39ºC (100 - 102ºF)
7
28
28
4
40 - 41ºC (104 - 106ºF)
9
36
36
5
42 - 43ºC (108 - 109ºF)
11
44
44
6
44 - 45ºC (111 - 113ºF)
13
52
52
7
46 - 47ºC (115 - 117ºF)
16
64
64
8
48 - 49ºC (118 - 120ºF)
19
76
76
9
50 - 51ºC (122 - 124ºF)
22
88
88
10
52 - 99ºC (126 - 210ºF)
25
100
100