--Maintenance & Adjustments--
Turbine Shut Off Adjustment
The turbine shut off slide stop see page 21 has been adjusted at the factory, however if it
has been disassembled, or changed and adjustment becomes necessary.
1.
Hold the shut off bar fully down against the level wind frame (See page 21).
2.
Pull the butterfly shaft lever to its extreme open position (mark on shaft end parallel
with turbine body, see illustration below on this page).
3.
Move the shut off slide stop against the rear tube of the shut off rod, and tighten
both set screws (See page 21).
4.
Exercise shut off bar to be sure that when it is depressed fully, the butterfly shaft
lever is latched in the open position.
Butterfly
shaft
lever
Turbine
body
Mark
- E37x1220 380,540 - 400,110 Operator Manual T37x1220 380,540 - 400,110 Operator Manual E33x1120 380,540 - 400,110 Operator Manual E30x1200 380,540 - 400,110 Operator Manual T33x1120 380,540 - 400,110 Operator Manual T30x1200 380,540 - 400,110 Operator Manual E30x980 380,540 - 400,110 Operator Manual T30x980 380,540 - 400,110 Operator Manual