Can transducer – JUMO 902910 CANtrans T RTD Temperature Probe with CANopen Output Data Sheet User Manual
Page 2

2010-06-11/00418901
Data sheet 90.2910
Page 2/4
JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14,
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany
Phone:
+49 661 6003-0
Fax:
+49 661 6003-607
E-mail:
Internet:
www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow - Essex CM20 2DY, UK
Phone: +44 1279 63 55 33
Fax:
+44 1279 63 52 62
E-mail:
Internet: www.jumo.co.uk
JUMO Process Control, Inc.
8 Technology Boulevard
Canastota, NY 13032, USA
Phone:
315-697-JUMO
1-800-554-JUMO
Fax:
315-697-5867
E-mail:
Internet: www.jumo.us
CAN transducer
Protocol
CiA DS 301, V4.02, CANopen Slave
Profile
CiA DS 404, V1.2 Measuring Devices and Closed-Loop Controllers
Baud rate
20kBaud to 1MBaud, setting via LSS or SDO
Module ID
1 to 127, setting via LSS or SDO
PDO
0 Rx, 1 Tx
SDO
1 Rx, 1 Tx
Emergency
yes
Heart Beat
yes
LSS
yes
SYNC
yes
Operation, project planning
All parameters are accessible via the CANopen object directory (EDS) and configurable via standard
CANopen software tools.
Input
Measurement input
Pt 1000 DIN EN 60 751, Class B
Measurement range limits
-50 to +150°C / -50 to +450°C
Measurement rate
250ms
Output
Output signal
CANopen per CiA DS 404 V1.2, in °C, can be changed to °F, K
Decimal place selectable 0, 1, 2
Transmission behavior
temperature linear
Electrical connection
Round plug M12x1, 5-pin per IEC 60 947-5-2
Voltage supply
Voltage supply
DC 10 to 30V
Current consumption
max. approx. 45mA
Monitoring
Measuring circuit
- Measured value underrange (freely selectable lower limit)
- Measured value overrange (freely selectable upper limit)
Probe short-circuit
Probe break
Additional functions
min./max. measured value memory
Precise adjustment
Change-over °C, °F, K
Decimal places selectable 0, 1, 2
Environmental influences
Operating temperature range
-20 to +85°C
Storage temperature range
-40 to +85°C
Temperature influence
≤ ± 0.0025% / K Deviation from 22°C of the measuring range span
Accuracy
Class B per DIN EN 60 751 max. ± 0.2% of the measuring range span
EMC
EN 61 326
Emitted interference, interference
resistance
Class B, industrial standard
Mechanical shock
per DIN IEC 68-2-27
EL 50mm -> 50g / 3ms; EL 100mm -> 30g / 3ms
(for type 902910/10)
EL 200mm -> 15g / 3ms
Mechanical vibrations
per DIN IEC 68-2-6
EL 50mm max. 10g at 10 to 2000Hz
(for type 902910/10)
EL 100mm max. 5g at 10 to 300Hz
EL 200mm max. 2g at 10 to 100Hz
Protection class
IP67, per EN 60 529, with connection plug screwed on