Order details – JUMO 902050 Screw-In RTD Temperature Probe with Connecting Cable Data Sheet User Manual
Page 3

2011-03-31/00311471
Data Sheet
90.2050 (90.2005)
Page 3/5
JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14,
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany
Phone:
+49 661 6003-0
Fax:
+49 661 6003-607
E-mail:
Internet:
www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow - Essex CM20 2DY, UK
Phone: +44 1279 63 55 33
Fax:
+44 1279 63 52 62
E-mail:
Internet: www.jumo.co.uk
JUMO Process Control, Inc.
8 Technology Boulevard
Canastota, NY 13032, USA
Phone:
315-697-JUMO
1-800-554-JUMO
Fax:
315-697-5867
E-mail:
Internet: www.jumo.us
Order details:
Screw-in RTD temperature probes with connecting cable
(1) Basic version
902050/10
Screw-in RTD temperature probe with fixed
screw fitting
902050/20
Screw-in RTD temperature probe with loose
screw fitting
(2) Operating temperature in °C / connecting cable
x x
130
-200 to +400°C / metal braiding
x x
380
-50 to +200°C / silicone
x x
386
-50 to +260°C / PTFE
x x
402
-50 to +400°C / metal braiding
x x
724
-5 to +80°C / PVC
x x
912
5 to 105°C / PVC (only with 1 x 2-wire or 3-wire circuit)
(3) Measuring insert
x x
1001
1 x Pt100 in 3-wire circuit
x x
1003
1 x Pt100 in 2-wire circuit
x x
1011
1 x Pt100 in 4-wire circuit
x x
2001
2 x Pt100 in 3-wire circuit
x x
2003
2 x Pt100 in 2-wire circuit
(4) Tolerance class to EN 60 751
x x
1
Class B (standard)
x x
2
Class A
(5) Protection tube diameter D in mm
x x
5
5mm
x x
6
6mm
(6) Fitting length EL in mm (50
≤
EL
≤
500)
x
17
17mm
x
37
37mm
x x
50
50mm
x x
100
100mm
x
137
137mm
x x
200
200mm
x
250
250mm
x x
...
please specify in plain text (50mm steps)
(7) Process connection
x
102
thread 1/4"pipe
x
104
thread 1/2"pipe
x
114
thread M 10 x 1
(8) Connecting cable end
x x
03
bare cable ends
x x
11
ferrules to DIN 46 228 Part 4 (standard)
x x
13
receptacle 6.3 to DIN 46 247
x x
80
multipole connector (please specify type in plain text)
x x
99
to customer specification
(9) Connecting cable length AL in mm (500
≤
AL
≤
500000)
x x
2500
2500mm
x x
...
please specify in plain text (500mm steps)
(10) Extra codes
x x
000
no extra code
x x
310
stepped protection tube
x x
315
cable protector: coil
x x
316
cable protector: tube
x x
317
shielded connecting cable
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
Order code
-
-
-
-
-
-
-
-
/
,...
Order example
902050/10 -
380
- 1001 -
1
-
6
-
100
-
104
-
11
- 2500 /
000
1
1.List extra codes in sequence, separated by commas.