Order details – JUMO 901210 Mineral-Insulated Thermocouple with Bare Connection Wires According to DIN 43710 and DIN EN 60584 Data Sheet User Manual
Page 6

2013-01-21/00073440
Data Sheet 901210
Page 6/11
JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany
Phone:
+49 661 6003-0
Fax:
+49 661 6003-607
E-mail:
Internet:
www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow, Essex CM20 2DY, UK
Phone: +44 1279 635533
Fax:
+44 1279 635262
E-mail:
Internet: www.jumo.co.uk
JUMO Process Control, Inc.
6733 Myers Road
East Syracuse, NY 13057, USA
Phone: 315-437-5866
1-800-554-5866
Fax:
315-437-5860
E-mail:
Internet: www.jumousa.com
Order details:
Mineral-insulated thermocouples according to DIN 43710 and DIN EN 60584
(1) Basic type
901220/40
Screw-in mineral-insulated thermocouple
with terminal head, form B
901220/41
Push-in mineral-insulated thermocouple
with terminal head, form B
(2) Measuring insert / operating temperature in °C
x x
1040
1× Fe-CuNi "J", operating temperature -200 to +800 °C, sheath material no. 1.4541
x x
1042
1× Fe-CuNi "L", operating temperature -200 to +800 °C, sheath material no. 1.4541
x x
1043
1× NiCr-Ni "K", operating temperature -200 to +1200 °C, sheath material no. 2.4816
x x
1048
1× NiCrSi-NiSi "N", operating temperature -200 to +1200 °C, sheath material no. 2.4816
x x
2042
2× Fe-CuNi "L", operating temperature -200 to +800 °C, sheath material no. 1.4541
x x
2043
2× NiCr-Ni "K", operating temperature -200 to +1200 °C, sheath material no. 2.4816
x x
2048
2× NiCrSi-NiSi "N", operating temperature -200 to +1200 °C, sheath material no. 2.4816
(3) Protection tube diameter D in mm
x x
3
Ø 3 mm
x x
4.5
Ø 4.5 mm (not for measuring insert type "N")
x x
6
Ø 6 mm
(4) Insertion length EL/NL in mm (50 to 50000 mm)
x x
100
100 mm
x x
200
200 mm
x x
300
300 mm
x x
400
400 mm
x x
500
500 mm
x x
...
Please specify in plain text (50 mm steps)
(5) Process connection
x
000
Without
x
103
Screw connection G 3/8
x
104
Screw connection G 1/2
(6) Extra codes
x x
000
Without
x x
309
Uninsulated construction (element welded to the base)
x x
320
Terminal head form BUZ
x x
331
1× programmable transmitter, 4 to 20 mA / 20 to 4 mA output, data sheet 707010
x x
336
1× programmable transmitter, 4 to 20 mA / 20 to 4 mA and HART
®
interface output, data sheet 707010
(1)
(2)
(3)
(4)
(5)
(6)
Order code
-
-
-
-
/
, ...
a
a
List extra codes in sequence, separated by commas.
Order example
901220/40 - 1040 -
3
-
100
-
104
/
000
- 901210 Mineral-Insulated Thermocouples with Form J Terminal Head According to DIN 43710 and DIN EN 60584 Data Sheet 901210 Mineral-Insulated Thermocouples with Standard Tab Connector According to DIN 43710 and DIN EN 60584 Data Sheet 901210 Mineral-Insulated Thermocouples with Compensating Cable According to DIN 43710 and DIN EN 60584 Data Sheet