Output (radio transmission)
Electrical data
Environmental influences
Transmitter in the B head with antenna-battery case
Probe ID
Max. 5-digit ID, factory-set, can be configured to customer-request
Transmission interval
Adjustable from 1 to 3600 s (factory setting: 15 s)
Transmission frequency
868.4 MHz (Europe)
Transmission power
+10 dBm
Open air range
Max. 300 m when using the antenna wall-holder of the receiver and the 3 m antenna
line. When installing the antenna directly on the receiver, a reduced range of approx.
40 % must be taken into account.
Output signal
Thermocouple
Voltage (mV)
RTD temperature probe
Resistance (
Ω
)
Resistance / potentiometer
Percent (%) or resistance (
Ω
)
Resistance transmitter
Percent (%)
Voltage
Voltage (mV)
Configuration
With setup program
Configurable parameters
Probe ID (max. 5-digit ID) and transmission interval
Voltage supply
Lithium battery
Rated voltage: 3.6 V, rated capacity: 2.2 Ah; size AA
Operating life
Approx. 1 year with the factory-set values (transmission interval = 15 s) and at room
temperature (brief transmission interval and high or low ambient temperature reduce
the battery operating life)
Battery change
Only use the lithium battery available as an accessory
Ambient temperature range
-30 to +85 °C
Storage temperature range / storage humidity
-40 to +85 °C / relative humidity
≤
95 %
Temperature influence
a
a
All accuracy values in % refer to the maximum measuring range.
Thermocouple
≤
± 0.005 % / K deviation from 22 °C plus accuracy of the cold junction
RTD temperature probe
≤
± 0.005 % / K deviation from 22 °C
Resistance / potentiometer
≤
± 0.01 % / K deviation from 22 °C
Resistance transmitter
≤
± 0.01 % / K deviation from 22 °C
Voltage
≤
± 0.005 % / K deviation from 22 °C
Climate class
10 cycles at 10 °C / 80 °C, according to IEC 68-2-30,
relative humidity 95 %, during operation
Vibration resistance
According to GL characteristic line 2
Admissible mechanical shock resistance
10 g / 6 ms, according to DIN IEC 68-2.29
Electromagnetic compatibility (EMC)
According to DIN EN 61326-1
Interference emission
Class B
Interference immunity
Industrial requirements
Radio frequency spectrum
ETSI EN 300 220-1 (V 2.3.1) and ETSI EN 300 220-2 (V 2.3.1)