beautypg.com

JUMO 707060 Wtrans B - Programmable Head Transmitter with Radio Transmission Data Sheet User Manual

Page 4

background image

2011-09-30/00532898

Data Sheet 707060

Seite 4/10

JUMO GmbH & Co. KG
Delivery address:Mackenrodtstraße 14,

36039 Fulda, Germany

Postal address: 36035 Fulda, Germany
Phone:

+49 661 6003-0

Fax:

+49 661 6003-607

E-mail:

[email protected]

Internet:

www.jumo.net

JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow, Essex CM20 2DY, UK
Phone: +44 1279 635533
Fax:

+44 1279 635262

E-mail:

[email protected]

Internet: www.jumo.co.uk

JUMO Process Control, Inc.
8 Technology Boulevard
Canastota, NY 13032, USA
Phone:

315-697-5866
1-800-554-JUMO

Fax:

315-697-5867

E-mail:

[email protected]

Internet: www.jumo.us

Resistance / potentiometer

Resistance transmitter

Voltage

Measuring circuit monitoring

MoRe5-MoRe41

0 to 2000 °C

± 0.2 %

Cold junction

Pt1000 internal

Cold junction accuracy

±

1 K

a

All accuracies given in % refer to the maximum measuring range

Designation

Measuring range

Measuring accuracy

a

a

All accuracies given in % refer to the maximum measuring range

Resistance / potentiometer
Linearization: 0 to 100 %

>

50

Ω

to

400

Ω

>

400

Ω

to

4000

Ω

>

4000

Ω

to

10000

Ω

±

400 m

Ω

±

4

Ω

±

10

Ω

Resistance / potentiometer
Linearization: Resistance in

Ω

> 50

Ω

to

10000

Ω

±

0.1 %

Connection type

2-wire or 3-wire circuit

Lead compensation

Not required for 3-wire circuit (max. admissible 11

Ω

per line).

Max. configurable lead wire resistance for 2-wire circuit: 22

Ω

.

Designation

Measuring range

Measuring accuracy

a

a

All accuracies given in % refer to the maximum measuring range

Resistance transmitter

>

50

Ω

to

400

Ω

>

400

Ω

to

4000

Ω

>

4000

Ω

to

10000

Ω

±

400 m

Ω

±

4

Ω

±

10

Ω

Connection type

3-wire connection

Requirement

R

e

+ R

a

+ R

s

10000

Ω

and R

e

+ R

a

1/3 R

s

Designation

Measuring range

Measuring accuracy

a

a

All accuracies given in % refer to the maximum measuring range

Voltage

0 to 50 mV

±

0.1 %

Measuring probe

Detection of
overrange / underrange

Detection of
probe /
cable short circuit

Detection of
probe /
cable break

Thermocouple

Yes / Yes

No

Yes

RTD temperature probe

Yes / Yes

Yes

Yes

Resistance / potentiometer

Yes / Yes

Yes

Yes

Resistance transmitter

No / No

No

No

Voltage

Yes / Yes

No

Yes

Designation

Standard

Measuring range

Measuring accuracy

a