Local lockout mode activation, Remote lockout mode activation, Short circuit and overload protection – Johnson Systems CS-SA Series Time Fade Stations User Manual
Page 10
10
Local Lockout Mode Activation
When the local lockout mode is activated, the control station is locked in the “OFF” state. Any
button press is ignored and the “OFF” LED flashes once to indicate local lockout mode is
activated.
Procedure:
• To activate the local lockout mode, press and hold the “OFF” button for approximately
10 seconds, until the “OFF” LED extinguishes.
• To deactivate the local lockout mode, press and hold the “OFF” button for approximately
10 seconds, until the “OFF” LED illuminates.
Remote Lockout Mode Activation
When the remote lockout mode is activated, the control station ignores all remote control station
key presses. The active LED flashes off for 0.1 seconds every 2 seconds to indicate remote
lockout mode is activated.
Procedure:
• To activate the remote lockout mode, press and hold the “DIM” button for approximately
10 seconds, until the “DIM” LED flashes off for 0.1 seconds.
• To deactivate the remote lockout mode, press and hold the “DIM” button for approximately
10 seconds, until the “DIM” LED flashes off for 0.1 seconds.
Short Circuit and Overload Protection
The control station is equipped with short circuit and overload protection. The short circuit limit is
set at 100mA with 0.6W of power dissipation. When a short circuit or overload is detected while in
the “ON” or “DIM” state, all of the button LED’s flash on and off to indicate there is a short circuit
or overload condition. The control station automatically recovers to normal operational state once
the short circuit or overload is removed.