beautypg.com

Bunn Trifecta 428220001E User Manual

Page 12

background image

Page 12

FRONT PANEL REMOVAL AND TANK DRAINING

Remove drip tray. Remove two screws.

Lower the panel as far as it will go.

Push the top down to clear the brew cham-

ber support arm, then pull the top out first.

Pull drain hose out as shown. Slide clamp

back and remove plug. Refer to program-

ming section and enter "Factory Blowout"

mode. Allow tank to drain into sink or

suitable container.

TANK DRAINING

RESET TO FIRST TIME SETUP

WARNING: DISCONNECT BREWER FROM POWER SOURCE BEFORE PANEL REMOVAL.

NOTE: If tank was drained, follow this procedure

before connecting brewer to power source.

Disconnect brewer from power source. Connect to

water supply. Install brew cup & chamber. Push and

hold both arrow buttons while plugging in the brewer.

When display reads "SET TO FIRST TIME UP", release

arrow buttons. Place a minimum 40 oz. container under

brew chamber. Press brew start button to begin cycle.

If tank was empty, it will expel only 20 oz. If tank was

still full, it will expel 40 oz.

42822.1 040810

WARNING

DISCONNECT BREWER

FROM WATER SUPPLY

BEFORE DRAINING