beautypg.com

Troubleshooting – Intelix AVO-USB User Manual

Page 3

background image

Troubleshooting 

If  your  equipment  malfunctions  with  the  AVO‐USB  extenders  in  place,  follow  the 
troubleshooting procedures below:  

 

1. Perform  diagnostics  on  your  equipment  by  following  the  manufacturer’s 

instructions.  

2. If connecting to a computer, shut down and restart the computer after connecting 

the source and destination devices through the AVO‐USB.  

3. If connecting to a computer, verify the connecting equipment’s drivers have been 

properly  installed.  Verify  by  connecting  the  equipment  directly  to  the  computer 
without the AVO‐USB inline.  

4. Check  all  connections  and  the  structured  cabling  system.  Verify  the  RJ45  crimp 

pattern conforms to either EIA/TIA 568A or 568B standards.  

5. Check the pin configuration on the structured cable.  

6. Verify your transmission rate does not exceed 12 Mbps.  

7. The maximum operational distances over which the AVO‐USB can be transmitted 

is  dependent  on  the  equipment  and  cabling.  Ensure  that  the  maximum 
recommended operational distances have not been exceeded.  

8. Check than only twisted pair patch cords are being used.  

9. Replace the AVO‐USB with another AVO‐USB set that is known to be working.  

10. If the above steps fail, please contact Intelix for support.  

11.