10. Circuit diagram
10.1 Supply voltage, switching outputs, analogue output
Model with 1 switching output
Model with 1 switching output and
1 analogue output
Plug to DIN 43650, 3 pole + earth
4 pole Binder plug, series 714 M18
4 pole plug, M12x1
4 pole plug, M12x1
Model with 2 switching outputs
Model with switching outputs
and 1 analogue output
4 pole Binder plug, series 714 M18
5 pole plug, M12x1
4 pole plug, M12x1
10.2 Connection diagram
Imax. 1.2 A
ETS 3X5-1
1
2
3
+
-
20..32 V
SP 1
Imax. 1.2 A
ETS 3X6-1
1
3
4
+
-
20..32 V
SP 1
Imax. 1.2 A
ETS 3X6-3
1
3
4
+
-
20..32 V
SP 1
RL
2
I = 4..20 mA
analogue
Imax. 1.2 A
ETS 3X4-2
1
2
3
+
-
20..32 V
4
Imax. 1.2 A
SP 1
SP 2
Imax. 1.2 A
ETS 3X4-3
1
2
3
+
-
20..32 V
4
SP 1
RL
I = 4..20 mA
analogue
Imax. 1.2 A
ETS 3X6-2
1
3
4
+
-
20..32 V
2
Imax. 1.2 A
SP 1
SP 2
Imax. 1.2 A
Imax. 1.2 A
SP 1
SP 2
ETS 3X8-5
1
3
4
+
-
20..32 V
5
2 I = 4..20 mA
analogue
RL