9. Technical specifications

Input data for built-in sensor:
Measuring range:

-25 .. 100 °C (-13 .. 212 °F)

Pressure resistance:

600 bar

Overload pressure:

900 bar

Hydraulic connection:

G1/2 A DIN 3852

Torque rating:

45 Nm

Parts in contact with medium:

stainless steel, seal: FPM

Input data for separate sensor:
Display range: *)

-30 .. 150 °C (-22 .. 302 °F)

Sensor connection:

connector M 12x1, 4-pole

Output data:
Accuracy (display, analogue output) £ ±1.0 °C (£ ±2.0 °F)

Temperature drift:

£ ±0.15 % /10 K (zero point and range)

Reaction time (T09):

approx. 20 s

Analogue output:

4 .. 20 mA, ohmic resistance

£ 400 W

Switching outputs:
Type:

PNP transistor output

Switching current:

max. 1.2 A

Switching cycles:

> 100 million

Ambient conditions:
Temperature range of medium:

-25 .. + 100 °C (built-in sensor)

Ambient temperature range:

-25 .. + 80 °C

Storage temperature range:

-40 .. + 80 °C

Nominal temperature range:

-10 .. + 70 °C

- mark:

EN 50081-1, EN 50081-2
EN 50082-1, EN 61000-6-2

Vibration resistance:

approx. 10 g / 0..500 Hz

Shock resistance:

approx. 50 g / 1ms

Other data:
Supply voltage:

20 .. 32 VDC

Current consumption:

approx. 100 mA (no switching output)

Safety type:

IP 65

Material of housing:

tube: stainless steel
keypad housing: PA6.6 Gf30

Display:

3-digit, 7-segment LED, red,
height of digits 9.2 mm

Weight:

approx. 300 g

Technical specifications - Accessories

Temperature sensor TFP 100
Temperature range of medium (for TFP 100):

-40 .. +125 °C / -40 .. +257°F

Electrical connection:

4-pole Binder plug, series 714 M18

Safety sleeve for tank-mounting the TFP 100
Parts in contact with medium:

All materials compatible with nickel

Note: *) Depending on the temperature range of the temperature sensor fitted, this can

reduce the display range of the ETS 300 with a separate sensor input.