E

General

Features

l

built-in pressure sensor with steel membrane

l

4-digit, 7-segment display to show the current pressure

l

analogue output, switchable 0..10 V or 4..20 mA as current source

l

two individually adjustable switching relays with change-over contacts

Installation options

l

directly into the system using a G ¼“ threaded connection,

or via a mechanical adapter into a G ½” pressure gauge connection

to DIN 16288

l

as a front panel unit where the connection is made via a hydraulic hose

Settings

Switching point settings:

l

Switching point and switching hysteresis relay 1 and relay 2

Basic settings:

l

Switching direction relay 1 and relay 2

l

Switching delay relay 1 and relay 2

l

Switch-back delay relay 1 and relay 2

l

Measured value filter on the display value

l

Standard display value (current pressure, switching point or peak value)

l

Analogue output signal (0..10 V or 4..20 mA)

Measuring range settings:

l

Upper and lower measuring range limit

Calibration options:

l

Re-calibration of the internal sensor for both zero and final value settings

l

Re-calibration of the signal range of the analogue output

Warranty

Both the components of the EDS 601 and the complete unit are subject to

stringent quality controls. Each EDS 601 is individually calibrated and subjected

to a final test. In this way we can guarantee that the unit is fault-free on despatch

and conforms to the given specifications. However, if there is cause for

complaint, please return the pressure switch to us outlining the fault.

Interference by anybody other than Hydac personnel will invalidate all warranty

claims.

Queries and problems

If you have any queries regarding technical details or the suitability of the

pressure switch for your application, please contact our sales/technical

department. The EDS 601 pressure switches are maintenance-free and should

operate perfectly when used according to the specifications

(see Technical Data). If faults do nonetheless arise, please contact the

Electronics Servicenter.