To Measure Pull
To determine the pull at a
corner pole by use of the C
Pull Finder, screw the short
arm A into the corner pole,
as illustrated in figure 2.
Adjust arm C so that the line
of sight, when sighting over
the back sight and the front
sight on arm C, is tangent to
the surface of the pole adja-
cent to the corner. In a simi-
lar manner, line up arm B,
sighting on the other pole
adjacent to the corner.
Check arm C to make cer-
tain it has not moved. The
pointer on arm B now indi-
cates, on the scale on arm
C, the pull in feet at the
corner.