General Machine Products 89010 Breeze Micro Fiber Cable Blowing Machine User Manual
Page 38

Page 38 of 43
General Machine Products Co., Inc.
Counter programming parameters for the Breeze machine:
Press RST Once:
Counter Parameters (1-INPUT)
INPA-B = Cnt ud - if correct press SEL.
CNT A DP = 0 - if correct press SEL
CNT A SCF = 0.0102 (METRIC, m) or 0.0335 (Imperial, ft) - once correct press & Hold SEL
CNT A RST = TO ZERO - if correct press SEL
CNT A DIR = NOR - if correct press SEL
CNT A LD = 0 - once correct press & Hold SEL
RST P– UP = NO - if correct press SEL
USER INP = NO - if correct press SEL
Press RST Twice
Rate Parameters (2-RATE)
RATE ENB = YES - if correct press SEL
RATE DP = 0 - if correct press SEL
RATE DSP = 60 - once correct press & Hold SEL
RATE INP = 97.9 (Metric, m/min) or 29.8 (Imperial, ft/min) - once correct press & Hold SEL
LO-UDT = 1.0 - if correct press SEL
HI-UDT = 2.0 - if correct press SEL
Press RST Three Times
DISPLAY (3-DSPLAY)
SEL ENB = YES - if correct press SEL
RST ENB = YES - if correct press SEL
D-SCROLL = NO - if correct press SEL
D-COLOR = RED - if correct press SEL
D-LEVEL = 5 - if correct press SEL
PRO CODE = 111—CODE REQUIRED TO RE-PROGRAM - once correct press & Hold SEL
CODE VER = NO - if correct press SEL
FACT SET = NO - Press SEL Twice