Manual EKS Electronic-Key Adapter Profibus-DP

8.3 Configuration

message

After the parameters for the Electronic-Key adapter have been set, the bus master sends a configuration
message. This message contains the configuration of the Electronic-Key adapter currently saved in the bus
master. The Electronic-Key adapter compares the configuration message received with its own values. If the
values match, the Electronic-Key adapter confirms the configuration.

8.4 Diagnostics

message

If the Electronic-Key adapter detects an error, it automatically signals that there is an error after changing the
status bytes using the diagnostics request "Extended diagnostics" to the bus master. The diagnostics data
received is saved in the diagnostics area of the bus master. The total length of the diagnostics message is 32
bytes.

Byte no. 8 of the diagnostics message contains the EKS diagnostics byte. The content of the EKS diagnostics
byte can be evaluated by the application.

Diagnostics area of the bus master

Byte no.

Function

Description

0

Station status 1

1

Station status 2

2

Station status 3

3 Diag_Master_Adr

Profibus

4 Ident-No_High

slave diagnostics

5

Ident-No_Low

6

Length of the extended diagnostics

Header

Extended diagnostics

7

SPC3 error

8

EKS diagnostics byte

9 - 13

EKS software release

14 – 18

Bus interface software release

Extended device

specific diagnostics

19 - 31

Internal device error

8.5 EKS diagnostics byte

The current state of the Electronic-Key adapter can be evaluated by the application via the content of the EKS
diagnostics byte (byte no. 8, see section 8.4 Diagnostics message) in the diagnostics area of the bus master.

Value

EKS

Description

diagnostics

byte

00

No error

hex

02

Electronic-Key not in the operating distance

hex

03

Parity bit error on Electronic-Key read-only

hex

06

Write process aborted. Start address or number of bytes is not a multiple of the block size 4

hex

Read attempt when the Electronic-Key adapter is set to Electronic-Key read-only and an Electronic-Key
read/write is inserted

18

hex

4x

General Electronic-Key communication error (renewed write or read necessary)

hex

50

Write attempt despite enabled write protection

hex

C6

hex

Area overflow on data read
(renewed write or read necessary)

C7

hex

Information!

A status change in the EKS diagnostics byte (value not 00

hex

) will cause bit no. 5 in status byte no. 0

being set in the input area of the bus master (job status see section 8.6.1).

092009-03-10/07

Subject to technical modifications