beautypg.com

2 connection of power supply, 3 connection of function earth, Manual eks electronic-key adapter profibus-dp – EUCHNER EKS FSA with Profibus-DP Interface User Manual

Page 18

background image

Manual EKS Electronic-Key Adapter Profibus-DP

6.2 Connection of power supply

(For information on pin assignment see section 4.3.2 Plug-in screw terminals for power supply)

It is imperative that the following points are observed:

f The connections must be made as appropriate to maintain EMC performance.
f A power supply of suitable EMC performance must be used for the power supply.
f Conductor cross-section maximum 1.5 mm².
f Tighten the terminal screws on the plug to 0.22 Nm.

6.3 Connection of function earth

The function earth is connected via terminal 3 on the plug-in screw terminals for the power supply. This
connection is electrically connected internally to the housing of the Electronic-Key adapter.

Information!

The function earth must be connected to PE!

6.4 Connection of the switched outputs (for EKS FSA only)

Warning!

Incorrect connection or errors in the safety-related integration of the EKS FSA can lead to fatal injury.
For this reason, observe the following safety aspects:

f It is not possible to generate a safe signal by using only the switched outputs LA1/LA2 and

LB1/LB2. Safe, downstream evaluation is always necessary (e. g. using a safety relay). Use of the
switched output LB1/LB2 as an alternative to the data line is optional.

f The safe evaluation must always be dual-channel. For this purpose, there are two alternatives:

1. Evaluation of output LA1/LA2 as channel LA together with an evaluation of the data line as

channel LB (recommended)

2. Evaluation of output LA1/LA2 as channel LA together with the output LB1/LB2 as channel LB

f Integrate

the

EKS

FSA as defined in the following connection examples from EUCHNER.

092009-03-10/07

Subject to technical modifications

Page 18

/

36

This manual is related to the following products: