4.4 DIP switch settings
The device address 0...126 (decimal) can be set using the DIP switches S1 to S7. The device address is given
by the sum of the address values on each DIP switch.
Write protection can be enabled using DIP switch S8. In this way the writing of data to the Electronic-Key
read/write is prevented.
Information!
The settings are only applied when the power supply is switched on.
DIP switches, 8-pole:
DIP
switch
Factory setting
Functions
address 3
S8
ON = write protection for Electronic-Key read/write
OFF
S7
ON = address
64 decimal
OFF
S6
ON = address
32 decimal
OFF
S5
ON = address
16 decimal
OFF
S4
ON = address
8 decimal
OFF
S3
ON = address
4 decimal
OFF
S2
ON = address
2 decimal
ON
S1
ON = address
1 decimal
ON
The device addresses 0 to 126 (decimal) are set using the following scheme:
1 2 3 4 5 6 7 8
ON
Device
LSB
MSB
address
S1
S2
S3
S4
S5
S6
S7
S8
0 OFF OFF OFF OFF OFF OFF OFF
1
ON OFF OFF OFF OFF OFF OFF
2 OFF ON OFF OFF OFF OFF OFF
3
ON ON OFF OFF OFF OFF OFF
:
32 OFF OFF OFF OFF OFF ON OFF
:
126 OFF ON ON ON ON ON ON
Write
protection
for
Electronic-
Key
read/write
Information!
The address 126 is only intended to be used for setup purposes.
4.5 LED
indicator
The Electronic-Key adapter operating states are indicated using a 3-color LED on the front.
Illumination of the LED in any color indicates the presence of the operating voltage.
Color
Operating state
Description
General bus error.
Red Fault
No communication with the bus master or error when the Electronic-Key is written or
read (e.g. due to premature removal of the key from the Electronic-Key adapter or a
faulty key).
The LED then flashes red for approx. 5 s. After this, the LED is illuminated green again
and the Electronic-Key adapter is again ready for use.
Green Ready
Communication with the bus master without Electronic-Key, Electronic-Key adapter
ready.
Yellow Electronic-Key
active
Communication with the bus master with Electronic-Key. There is an Electronic-Key in
the Electronic-Key adapter and it has been detected.
092009-03-10/07
Subject to technical modifications
Page 14
/