EUCHNER HKC User Manual
Page 3

Operating instructions for electronic handwheel HKC
Correct use
The EUCHNER handwheel is a universal pulse gen-
erator for manual shaft positioning.
The handwheel is primarily used for positioning NC-
driven machine tools during set-up.
Handwheels are used as part of an overall higher-
level control system.
Their use, installation and operation are permissible
only in conformity with these Operating Instruc-
tions.
Correct use includes compliance with the relevant
requirements for installation and operation, in
particular
EN 60204, electrical equipment of machines
EN 12100, safety of machines, general design
principles
EN ISO 13849-1, safety-related parts of control
systems
Safety precautions
EUCHNER handwheels HKC meet the EMC protec-
tion requirements according to EN 61000-6-2 and
EN 61000-6-4.
Handwheels HKC must not be used for residential
applications, in business or commercial areas or
in small businesses.
Appropriate safety measures must be taken to
prevent a malfunction of the handwheel which
could cause danger to human beings or dam-
age to operating equipment.
Function
Two square-wave outputs of 100 or 25 pulses per
revolution are available for the user.
A second phase-shifted output allows the connected
control to detect the direction of movement.
The pulses are evaluated in the control.
The detent mechanism is magnetic and is therefore
totally wear-free.
Assembly
The unit may only be assembled by authorised
personnel.
The handwheel is assembled with nuts on 3 threaded
M3 bolts.
Fig. 1: Handwheel installation
Electrical connection
Electrical connection may only be performed by
authorised personnel trained in EMC with the
machine switched off and in de-energised
state.
The machine must be safeguarded against
reactivation.
If connected incorrectly, the handwheel
may be damaged.
Observe electrical characteristics and the pin
assignments (see technical data)
Always shield connecting leads.
Ground the shield at the end of the lead at a central
grounding point, e.g. in the distribution board or in
the control cabinet, over a large surface, with low
resistance and with low inductance.
Apply shielding to handwheel screw terminal pin y.
Do not install connecting leads in the immediate
vicinity of interference sources.
When installing connections, the operator must
ensure compliance with the EMC safety require-
ments.
Authorisation according to
: operation with
power supply of UL-class 2 only, housing type
UL-type 1.
Service and inspection
EUCHNER handwheels require no maintenance.
Handwheels may only be repaired by the manu-
facturer.
To clean the handwheels, only use solvent-free clean-
ing agents and a soft cloth.
Disclaimer of liability
The company does not accept liability regarding the
following cases:
if the unit is not used for its intended purpose
if the safety instructions are not followed
if the units are electrically connected by unautho-
rised personnel
if the units are tampered with
Instructions for counting the handwheel
pulses: Handwheel HKC
The following options are recommended for counting
the handwheel pulses:
suitable counter module
phase discriminator
Do not open the
handwheels!
Do not throw or drop the
handwheels!
Do not hit the handwheels!
Do not use tools on the
handwheels!