Exclusion of liability and warranty, Possible combinations on the ar evaluation unit, 4important – EUCHNER CES-AR-AES-12 User Manual
Page 4

Operating Instructions AR Evaluation Unit CES-AR-AES-12
4
Important!
Ì
In the case of series connection of more than 11 switches in a chain,
the PFH
d
can be calculated according to one of the stated methods in
EN ISO 13849-1:2008, Section 4.5.1.
Ì
If the simplified method according to Section 6.3 of EN ISO 13849:2008-12
is used for validation, the Performance Level (PL) might be reduced when
more than 11 devices are connected in series.
Ì
It is only allowed to use components that are permissible in accordance with
the table below.
Possible combinations on the AR evaluation unit
Evaluation unit
Safety switch
Actuator
CES-A-BBA
071
840
CES-A-BCA
088
786
CES-A-BP
A
098
775
CES-A-BRN
100
251
CES-A-BLN-R2-100776
100
776
CES-A-BLN-L2-104510
104
510
CES-A-BLN-U2-103450
103
450
CES-A-BDN-06-104730
104
730
CET
-A-BWK-50X
096
327
AR evaluation unit
CES-AR-AES-12
098 225
CES-AR-C01...
from V1.1.2
(see rating plate on
the device)
CES-AR-CR2...
from V1.1.2
(see rating plate on
the device)
CES-AR-CL2...
from V1.1.2
(see rating plate on
the device)
CET1/2-AR...
from V1.1.2
(see rating plate on
the device)
CET3/4-AR...
from V1.0.0
(see rating plate on
the device)
Key to symbols
/
Combination possible / combination on request
Combination possible, guard locking for process protection
/
Combination possible, guard locking for personal protection / combination on request
Combination not permissible
Exclusion of liability and warranty
In case of failure to comply with the conditions for correct use stated above, or
if the safety instructions are not followed, or if any servicing is not performed as
required, liability will be excluded and the warranty void.