Operating Instructions AR Evaluation Unit CES-AR-AES-12
17
System status table
Operating mode
Actuator/ guar
d position
Safety outputs
OA and OB
Indicator LEDs
Door monitor-
ing outputs
State
DIA (r
ed)
OUT (yel
-
low)
ST
ATE
(gr
een)
OUT AR
DIA
Self-test
X
off
15 Hz
(8 s)
off
off
Self-test after power up
Normal operation
open
off
off
off
Normal operation, at least one door open
closed
On
On
off
Normal operation, all doors closed
closed
off
3 Hz
On
off
Normal operation, all doors closed, start button not
pressed
or fault in the feedback loop
closed
off
4 x
On
On
Normal operation, all doors closed, feedback loop
was open during attempt to start
X
X
X
7 x
off
On
Faulty data transmission for status signals (safety
circuit not affected)
Fault display
X
off
1 x
off
On
Fault in the AR switch chain (e.g. fault on starting the
switch chain or more than 12 devices connected)
X
off
2 x
off
On
Fault on the safety outputs or on the start button
(e.g. start configuration changed in operation, no/
erroneous signals from the switch chain, broken
cable on one of the channels I
A
or I
B
, or short circuit/
ground fault on one of the cables I
A
or I
B
)
X
off
4 x
off
On
Fault on the safety relay, re-start device.
If fault is still indicated, contact manufacturer.
X
off
5 x
off
On
I
nternal component fault, re-start device.
If fault is still indicated, contact manufacturer.
X
off
6 x
off
On
-
Fault in feedback loop, e.g.
-
feedback loop not connected on power up
-
missing jumper between Y1/Y2
or
-
Fault in the start button, e.g.
-
on autostart: jumper between S/U
B
instead of S/
Y1
-
Start button stuck
X
off
off
On
Start failed three times, contact manufacturer
Key to symbols
LED not illuminated
LED illuminated
15 Hz (8 s)
LED flashes for 8 seconds at 15 Hz
3 x
LED flashes three times
X
Any state