12
If a feedback loop is not to be connected, a jumper must be fitted to the terminals
Y1 and Y2 (see Figure 7).
CES-AR-AES
33 43
23
13
Y2
Y1
24 34 44
14
+24 V
Subsequent
devices
(e.g. contactors)
Fig. 7: Safety contacts connected and jumper on the feedback loop
The following conditions must be met for the safety contacts to be closed:
For manual start
Ì
The feedback loop is closed
Ì
The start button has been pressed and released (switches on falling edge)
Ì
All safety doors closed
For automatic start
Ì
The feedback loop is closed
Ì
All safety doors closed
If the feedback loop is open, the
DIA LED flashes and the STATE LED is lit
(see
section Troubleshooting). The monitoring output DIA is set.
The safety contacts remain open if the feedback loop is open at the start. The unit
switches to fault state, the DIA LED illuminates, and the STATE LED flashes (see
section Troubleshooting).
- N1A Single hole fixing limit switch (12 pages)
- NZ Safety switch (12 pages)
- NZ.VZ (15 pages)
- NZ.VZ-xxxVS (16 pages)
- TZxxxAS1 (16 pages)
- TZxxx (20 pages)
- NXxxx (12 pages)
- TXxxx (12 pages)
- SGAxxx (12 pages)
- STAxxx (15 pages)
- STA-TWxxx (Twin) (15 pages)
- NMxxAV/AL (8 pages)
- NMxxWO/RB (12 pages)
- NMxxKB (12 pages)
- NMxxHB (12 pages)
- NMxxAK/AG (8 pages)
- NMxxVZ (15 pages)
- NP (12 pages)
- GPxxx (12 pages)
- TPxxx (12 pages)
- SGPxxx (12 pages)
- SGP-TWxxx (Twin) (12 pages)
- STP-TWxxx (Twin) (15 pages)
- STPxxx (15 pages)
- STP-BIxxx (12 pages)
- STMxxx (12 pages)
- NQxxVZ (8 pages)
- TQxxx (12 pages)
- TKxxx (12 pages)
- ESH (8 pages)
- Hinge ESH Re-adjustable (8 pages)
- MGB-AR (14 pages)
- MGB-L1-xxxARx-xxx (38 pages)
- MGB-L0-xxxARx-xxx (36 pages)
- MGB-LxxB-PNx-xxx (PROFINET) with Data Structure Type B (44 pages)
- MGB-LxxB-PNA-xxx (PROFINET) with Data Structure Type A (36 pages)
- CES-A-ABA-01 (Unicode) (42 pages)
- CES-Axxx (5 pages)
- CES-A-AEA-02B (Unicode) (44 pages)
- CES-A-UBA-01 (Multicode) (40 pages)
- CES-A-UEA-02B (Multicode) (44 pages)
- CES-AZ-ABS-01B (Unicode) (40 pages)
- CES-AZ-UBS-01B (Multicode) (38 pages)
- CES-AZ-AES-xxx (Unicode) (54 pages)
- CES-AZ-UES-xxx (Multicode) (56 pages)