Technical data, Technical data for safety switch cet.-ar-c..-ah – EUCHNER CETx-AR-xxx-AH-xxx (Unicode) User Manual
Page 40
Operating Instructions Safety Switch CET.-AR-...-AH-...
40
Technical data
Note:
If a product data sheet is included with the product, the information on the data
sheet applies in case of discrepancies with the operating instructions.
Technical data for safety switch CET.-AR-C..-AH-...
Parameter
Value
Unit
min.
typ.
max.
General
Material, slide
Stainless steel
Material, safety switch housing
Die-cast aluminum
Installation position
Any (recommendation: switch head downward)
Degree of protection
with plug connector M12
IP67
with plug connector RC18
IP65
(screwed tight with the related mating connector)
Safety class
III
Degree of contamination
3
Mechanical life
1 x 10
6
operating cycles
Ambient temperature at U
B
-20
-
+55
°C
Actuator approach speed, max.
20
m/min
Locking force F
max
6500
N
Locking force F
Zh
in acc. with GS-ET-19
F
Zh
= F
max
/1.3 = 5000
N
Weight
approx. 1.0
kg
Degrees of freedom (actuator in recess) X, Y, Z
X, Y ± 5; Z ± 4
mm
Connection type (depending on version)
2 plug connectors M12, 5 and 8-pin
1 plug connector RC 18, 19-pin (as yet no UL approval)
Operating voltage U
B
(reverse polarity protected, regulated,
residual ripple < 5%)
24 ± 15% (PELV)
V DC
Current consumption I
B
80
mA
For the approval according to UL the following applies
Operation only with UL class 2 power supply, or equivalent measures
Switching load according to UL
DC 24 V, class 2
External fuse (operating voltage U
B
)
0.25
-
2
A
External fuse (solenoid operating voltage U
CM
)
0.5
-
8
A
Rated insulation voltage U
i
-
-
75
V
Resilience to vibration
In acc. with EN 60947-5-2
EMC protection requirements
In acc. with EN IEC 60947-5-3
Safety outputs OA/OB
Semiconductor outputs, p-switching, short circuit-proof
- Output voltage U
OA
/U
OB
1)
V DC
HIGH
U
OA
/U
OB
U
B
- 1.5
-
U
B
LOW
U
OA
/U
OB
0
-
1
Switching current per safety output
1
-
200
mA
Utilization category according to EN 60947-5-2
DC-13 24V 200mA
Caution: outputs must be protected with a free-wheeling diode in case of inductive loads
Switching frequency
0.5
Hz
Repeat accuracy R acc. to EN IEC 60947-5-3
≤ 10
%
Monitoring outputs OUT and OUT D (optional)
p-switching, short circuit-proof
Output voltage
0.8 x U
B
-
U
B
V DC
Max. load
-
-
50
mA
Teach-in input J or input feedback loop Y
HIGH
15
-
U
CM
V
LOW
0
-
1
Solenoid
Solenoid operating voltage U
CM
(reverse polarity protected,
regulated, residual ripple < 5%)
DC 24 V +10%/-15%
Current consumption solenoid I
CM
480
mA
Power consumption
10
W
Duty cycle
100
%
Freely configurable LEDs
2)
LED1 red, LED2 green
Operating voltage
20.4
-
26.4
V DC
Reliability values according to EN ISO 13849-1
Head downward or horizontal
Head upward
Category
4
3
Performance Level (PL)
e
e
PFH
d
3.1 x 10
-9
/ h
4.29 x 10
-8
/ h
Mission time
20
20
years
1) Values at a switching current of 50 mA without taking into account the cable lengths.
2) Can vary depending on version. See data sheet.