System status table – EUCHNER CETx-AR-xxx-AH-xxx (Unicode) User Manual
Page 39
Operating Instructions Safety Switch CET.-AR-...-AH-...
39
System status table
Operating mode
Actuator/
door
position
Safety
outputs
OA
and
OB
Monitoring
output
OUT
Door
monitoring
output
OUT
D
(only
CET3
and
CET4)
LED indicator
output
State
ST
ATE
(gr
een)
DIA
(r
ed)
Self-test
X
off
off
off
10 Hz
(8 s)
Self-test after power up
Normal operation
closed
on
on
on
Normal operation, door closed and locked
closed
off
on
on
1 x in-
verse
Normal operation, door closed and locked, safety outputs not switched
because:
- Preceding device in the switch chain signals "door open" (only with series
connection)
- Feedback loop not closed
closed
off
off
on
1 x
Normal operation, door closed and not locked
open
off
off
off
1 x
Normal operation, door open
Teach-in standby
open
off
off
off
3 x
Door open; device is ready to learn a new actuator.
(only a short time after power up)
Setup
closed
off
off
off
1 Hz
Teach-in operation
X
off
off
off
Positive acknowledgment after completion of teach-in operation
Fault display
X
off
off
off
1 x
Error in teach-in operation
(e.g. actuator removed from the operating distance prior to the end of the
teach-in operation or disabled actuator in the operating distance or no actua-
tor detected at the teach-in input after 3 min.
X
off
off
off
2 x
Input fault
(e.g. missing test pulses, illogical switch state from previous switch in the
switch chain)
X
off
off
off
4 x
Output fault
(e.g. short circuit, loss of switching ability)
X
off
off
off
5 x
Internal fault
(e.g. component fault, data error or short circuit at the outputs)
X
off
off
off
X
X
Internal fault
Key to symbols
LED not illuminated
LED illuminated
10 Hz (8 s)
LED flashes for 8 seconds at 10 Hz
3 x
LED flashes three times, and this is then repeated
X
Any state
After the cause has been remedied, faults can generally be reset by opening and
closing the door. If the fault is still displayed afterward, use the reset function or
briefly interrupt the power supply. Please contact the manufacturer if the fault could
not be reset after restarting.
Important:
If you do not find the displayed device status in the System status table, this indi-
cates an internal device fault. In this case, you should contact the manufacturer.