Operating Instructions Safety Switch CET.-AR-...-AH-...
11
Escape release (optional)
Important:
Ì
The escape release is not a safety function.
Ì
The machine manufacturer must select and use a suitable release (escape
release, emergency unlocking, etc.) for a specific application. A risk assess-
ment appraisal is required for this purpose. It may be necessary to take
specifications from a product standard into account.
Ì
The correct function must be checked at regular intervals.
Ì
Loss of the release function due to tension on the actuator. The door must
not be under tension during release.
Ì
Please observe the notes on any enclosed data sheets.
The escape release is used to open a locked safety guard from the inside (see
dimension drawing in the section Technical data).
Fit escape release such that operation, inspection and maintenance are possible.
Using the escape release
Ì
Press the red release knob to the stop
¨
The safety device can be opened
Pull the knob out again to reset.
The monitoring output OUT is switched off; OUT D can assume an undefined state.
Open the safety door and close it again after resetting the escape release. The
device will then operate normally again.