Operating Instructions Read Head CET-AX with Guard Locking and Guard Locking Monitoring

74,5 ± 4 mm

Anfahrbereich/

Approach Zone

Figure 3: Door radii and approach zone

!

= 90°

min R300

min R800

Alternative solutions must comply with the following

requirements:

f

Electrically isolated power supply unit with a max.

open-circuit voltage of 30 V/DC and a limited

current of max. 8 A.

f

Electrically isolated power supply unit in combina-

tion with fuse as per UL248. This fuse should be

designed for max. 3.3 A and should be integrated

into the 30 V DC voltage section.

In order to avoid EMC interference, the physical

environmental and operating conditions at the

installation site of the device must comply with

the requirements according to the standard

EN 60204-1:2006, section 4.4.2 (EMC).

f

For terminal assignment see Figure 4.

f

For detailed information see the system manual

for the evaluation unit used.

Setup and functional check

Pay attention to the information in the system manual

for the evaluation unit used during setup.

Danger of fatal injuries as a result of faults in

installation and functional check.

f

Before carrying out the functional check,

make sure that there are no persons in the

danger area.

f

Observe the valid accident prevention regula-

tions.

f

Mechanical function test

The actuator must slide easily into the recess on

the actuating head. Close the safety guard several

times to check the function.

f

Electrical function test

After installation and any fault, the safety function

must be fully checked. Proceed as follows:
1. Switch on operating voltage.

f

The machine must not start automatically.

2. Close all safety guards.

Guard locking by solenoid force: Activate

guard locking.

f

The machine must not start automatically. It

must not be possible to open the safety guard.

3. Enable operation in the control system.

f

It must not be possible to deactivate the guard

locking as long as operation is enabled.

4. Disable operation in the control system and

deactivate guard locking.

f

The guard locking must remain active until there

is no longer any risk of injury.

f

It must not be possible to start the machine as

long as the guard locking is deactivated.

Service and inspection

Warning:
Loss of the safety function because of damage

to the system.
In case of damage, the entire device must be

replaced.
Only accessories or spare parts that can be ordered

from EUCHNER may be replaced.
Regular inspection of the following is necessary to

ensure trouble-free long-term operation:

f

Check the switching function (see section Functional

check)

f

Check all additional functions (e.g. escape release,

lockout mechanism, etc.)

f

Check the secure fastening of the devices and the

connections

f

Check for soiling

No servicing is required, repairs to the device are only

allowed to be made by the manufacturer.

Note:
The year of manufacture can be seen in the lower right

corner of the type plate.

Exclusion of liability under the following

circumstances

f

incorrect use

f

non-compliance with safety regulations

f

installation and electrical connection not per-

formed by authorized personnel

f

failure to perform functional checks.

Technical data

f

Read head

Parameter

Value

Material

- Slide

- Read head housing

Stainless steel

Die-cast aluminum

Installation position

Any (recommendation: actuat-

ing head downward)

Degree of protection acc. to

IEC 60529

IP67 (screwed tight with the

related mating connector)

Mechanical life

1 x 10

6

operating cycles

Ambient temperature

-20 ... +55 °C

Actuator approach speed,

max.

20 m/min

Locking force, max.

6,500 N

Locking force F

Zh

in acc. with GS-ET-19

F

Zh

=

F

max

= 5,000

1.3

Weight

Approx. 1 kg

Degrees of freedom X, Y, Z

X, Y ± 5 mm; Z ± 4 mm

Switching frequency

1 Hz (this value can deviate

depending on the evalua-

tion unit used. See system

documentation of the related

evaluation unit)

Connection

See Figure 4

Rated insulation

voltage U

i

50 V

Rated impulse withstand

voltage U

imp

1.5 kV

Solenoid
Connection

Reverse polarity protected

Solenoid operating voltage/

Solenoid power consumption

DC 24 V +10% -15% 10 W

Duty cycle

100 %

f

Actuator

Parameter

Value

Housing material

Stainless steel

Installation position

Active face opposite read head

Degree of protection acc. to

IEC/EN 60529

IP67

Mechanical life

1 x 10

6

operating cycles

Ambient temperature

-20 ... +55 °C

Locking force, max.

6,500 N

Weight

Approx. 0.25 kg

Stroke max.

15 mm

Door radius, min.

300 mm

Power supply

Inductive, via read head

f

LED

Parameter

Value

Connection voltage

24 V ± 15 % (reverse polarity

protected)

Current consumption, max.

6 mA