Read head ces-a-lmn-sc, Dimension drawing, Typical operating distance – EUCHNER CES-A-ABA-01B (Unicode) User Manual
Page 31: Cylindrical design m12

Operating Instructions Safety System CES-A-ABA-01/CES-A-ABA-01B
31
Read head CES-A-LMN-SC
Ì
Cylindrical design M12
Ì
M8 plug connector (snap-action and screw terminals)
Ì
In combination with CES-A-BMB actuator
Dimension drawing
Note
The read head is allowed to be installed as a maximum up to the clear zone (area
of the active face without metal housing).
Typical operating distance
With evaluation unit CES-A-ABA-01 and actuator CES-A-BMB
With evaluation unit CES-A-ABA-01B and actuator CES-A-BMB
Note
A minimum distance of s = 1.2 mm must be maintained.
Approvals
17
5
32
19,
7
R eading distance s
C
entre offset
m
connected
35
4
8
30
M1
2x
1
M8x
1
37
1)
1)
Active face
1) Clear zone (area of the active face without metal housing)
-4
-2
-3
-1
1
3
2
4
0
1
2
3
4
Centre offset m [mm]
Distance s [mm]
OFF
ON
Actuator
Read
head
s
m
Hysteresis
Switch-on
distance
ON
OFF
Hysteresis
Distance s
S
ao
Output state
Switch-off
distance
OFF
-4
-6
-2
0
Centre offset m [mm]
Distance s [mm]
OFF
ON
Switch-on
distance
ON
OFF
Hysteresis
Distance s
S
ao
Output state
Switch-off
distance
OFF
-8
2
8
6
4
2
4
6
8
Actuator
Read
head
s
m
not permissible area
not permissible area
Hysteresis