beautypg.com

Read head ces-a-lmn-sc, Dimension drawing, Typical operating distance – EUCHNER CES-A-ABA-01B (Unicode) User Manual

Page 31: Cylindrical design m12

background image

Operating Instructions Safety System CES-A-ABA-01/CES-A-ABA-01B

31

Read head CES-A-LMN-SC

Ì

Cylindrical design M12

Ì

M8 plug connector (snap-action and screw terminals)

Ì

In combination with CES-A-BMB actuator

Dimension drawing

Note

The read head is allowed to be installed as a maximum up to the clear zone (area
of the active face without metal housing).

Typical operating distance

With evaluation unit CES-A-ABA-01 and actuator CES-A-BMB

With evaluation unit CES-A-ABA-01B and actuator CES-A-BMB

Note

A minimum distance of s = 1.2 mm must be maintained.

Approvals

17

5

32

19,

7

R eading distance s

C

entre offset

m

connected

35

4

8

30

M1

2x

1

M8x

1

37

1)

1)

Active face

1) Clear zone (area of the active face without metal housing)

-4

-2

-3

-1

1

3

2

4

0

1

2

3

4

Centre offset m [mm]

Distance s [mm]

OFF

ON

Actuator

Read
head

s

m

Hysteresis

Switch-on
distance

ON

OFF

Hysteresis

Distance s

S

ao

Output state

Switch-off
distance

OFF

-4

-6

-2

0

Centre offset m [mm]

Distance s [mm]

OFF

ON

Switch-on
distance

ON

OFF

Hysteresis

Distance s

S

ao

Output state

Switch-off
distance

OFF

-8

2

8

6

4

2

4

6

8

Actuator

Read
head

s

m

not permissible area

not permissible area

Hysteresis

This manual is related to the following products: