EUCHNER CES-A-ABA-01B (Unicode) User Manual
Page 15

Operating Instructions Safety System CES-A-ABA-01/CES-A-ABA-01B
15
Carrying out teach-in for first actuator
(state on delivery)
1. Apply the operating voltage to the evaluation unit
Ì
green LED flashes fast (approx. 4 Hz)
2. Move actuator to the read head (observe distance < S
ao
)
Ì
teach-in operation starts, green LED flashes slowly (approx. 1 Hz)
3. Teach-in operation completed (after 60 seconds)
Ì
green LED goes out
4. To activate the actuator code from the teach-in operation in the evaluation unit,
the operating voltage must then be switched off at the evaluation unit for min.
10 seconds.
5. Check functioning of the safety guard.
Carrying out teach-in for a new actuator
1. Apply the operating voltage to the evaluation unit
2. Move new actuator to the read head (observe distance < S
ao
)
Ì
teach-in operation starts, green LED flashes (approx. 1 Hz)
3. Teach-in operation completed (after 60 seconds)
Ì
green LED goes out, new code saved, old code deactivated
4. To activate the new actuator code from the teach-in operation in the evaluation
unit, the operating voltage must then be switched off for min. 10 seconds.
5. Check functioning of the safety guard.