beautypg.com

12 technical data, Technical data – EUCHNER MGB-L0-xxxAPx-xxx User Manual

Page 28

background image

28

Operating Instructions MGB-L0...AR.-... and MGB-L0...AP.-...

12 Technical data

Note:

If a product data sheet is included with the product, the information on the data

sheet applies in case of discrepancies with the operating instructions.

Parameter

Value

Unit

Housing material

Glass fiber reinforced plastic

die-cast zinc, nickel-plated

Stainless steel

Dimensions

See section 6.4 Dimension drawing, page 9

Weight

Interlocking module

Handle module

Escape release

0.75

1.00

0.50

kg

Ambient temperature at U

B

= DC 24 V

-20 .... +55

°C

Degree of protection

Cover not populated/populated with buttons/indicators

Cover populated with key-operated switch

Cover populated with key-operated switch FS22

IP65

IP54

IP42

Safety class

III

Degree of contamination

3

Installation position

Any

Connection

4 cable entries M20x1.5 or plug connector

Conductor cross-section (rigid/flexible)

- With ferrule according to DIN 46 228/1

- With ferrule with collar according to DIN 46

228/1

0.13 ... 1.5 (AWG 24 ... AWG 16)

0.25 ... 1.5

0.25 ... 0.75

mm²

Operating voltage UB (reverse polarity protected,

regulated, residual ripple < 5 %)

24 +10% / -15% (PELV)

V DC

Auxiliary power UA (reverse polarity protected,

regulated, residual ripple < 5 %)

24 +10% / -15% (PELV)

V DC

Current consumption I

UB

(no load on any outputs)

80

mA

Current consumption I

UA

- Push button S (no load, per LED)

5

External fuse

See section 10.2 Fuse protection for power supply, page 18

Safety outputs FO1A/FO1B

Semiconductor outputs, p-switching, short circuit-proof

Test duration after power on

AR < 1000 / AP < 300

µs

Output voltage U

FO1A

/ U

FO1B

1)

HIGH

U

FO1A

/ U

FO1B

U

B

-2V ... U

B

LOW

U

FO1A

/ U

FO1B

0 ... 1

V DC

Switching current per safety output

1 ... 200

mA

Utilization category according to EN IEC 60947-5-2

DC-13 24 V 200 mA

Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.

Classification acc. to EN IEC 60947-5-3

PDF-M

Monitoring outputs

- Output voltage

1)

- Max. load

p-switching, short circuit-proof

U

A

- 2V ... U

A

max. 50

mA

Rated insulation voltage U

i

30

V

Rated impulse withstand voltage U

imp

1.5

kV

Resilience to vibration

In acc. with EN IEC 60947-5-3

Switching frequency

0.25

Hz

EMC protection requirements

In acc. with EN IEC 60947-5-3

Reliability values according to EN ISO 13849-1

Category

4

Performance Level

PL e

PFH

d

3.1 x 10

-9

/ h

2)

Mission time

20

years

Controls and indicators

Operating voltage

5 … 24

V

Operating current

1 … 100

mA

Breaking capacity max.

250

mW

Power supply LED

24

V DC

1) Values at a switching current of 50 mA without taking into account the cable lengths.
2) Applying the limit value from EN ISO 13849-1:2008, section 4.5.2 (MTTF

d

= max. 100 years), the employers' liability insurance

association certifies a PFH

d

of max. 2.47 x 10

-8

.

This manual is related to the following products: