12 technical data, Technical data – EUCHNER MGB-L0-xxxAPx-xxx User Manual
Page 28
28
Operating Instructions MGB-L0...AR.-... and MGB-L0...AP.-...
12 Technical data
Note:
If a product data sheet is included with the product, the information on the data
sheet applies in case of discrepancies with the operating instructions.
Parameter
Value
Unit
Housing material
Glass fiber reinforced plastic
die-cast zinc, nickel-plated
Stainless steel
Dimensions
See section 6.4 Dimension drawing, page 9
Weight
Interlocking module
Handle module
Escape release
0.75
1.00
0.50
kg
Ambient temperature at U
B
= DC 24 V
-20 .... +55
°C
Degree of protection
Cover not populated/populated with buttons/indicators
Cover populated with key-operated switch
Cover populated with key-operated switch FS22
IP65
IP54
IP42
Safety class
III
Degree of contamination
3
Installation position
Any
Connection
4 cable entries M20x1.5 or plug connector
Conductor cross-section (rigid/flexible)
- With ferrule according to DIN 46 228/1
- With ferrule with collar according to DIN 46
228/1
0.13 ... 1.5 (AWG 24 ... AWG 16)
0.25 ... 1.5
0.25 ... 0.75
mm²
Operating voltage UB (reverse polarity protected,
regulated, residual ripple < 5 %)
24 +10% / -15% (PELV)
V DC
Auxiliary power UA (reverse polarity protected,
regulated, residual ripple < 5 %)
24 +10% / -15% (PELV)
V DC
Current consumption I
UB
(no load on any outputs)
80
mA
Current consumption I
UA
- Push button S (no load, per LED)
5
External fuse
See section 10.2 Fuse protection for power supply, page 18
Safety outputs FO1A/FO1B
Semiconductor outputs, p-switching, short circuit-proof
Test duration after power on
AR < 1000 / AP < 300
µs
Output voltage U
FO1A
/ U
FO1B
1)
HIGH
U
FO1A
/ U
FO1B
U
B
-2V ... U
B
LOW
U
FO1A
/ U
FO1B
0 ... 1
V DC
Switching current per safety output
1 ... 200
mA
Utilization category according to EN IEC 60947-5-2
DC-13 24 V 200 mA
Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.
Classification acc. to EN IEC 60947-5-3
PDF-M
Monitoring outputs
- Output voltage
1)
- Max. load
p-switching, short circuit-proof
U
A
- 2V ... U
A
max. 50
mA
Rated insulation voltage U
i
30
V
Rated impulse withstand voltage U
imp
1.5
kV
Resilience to vibration
In acc. with EN IEC 60947-5-3
Switching frequency
0.25
Hz
EMC protection requirements
In acc. with EN IEC 60947-5-3
Reliability values according to EN ISO 13849-1
Category
4
Performance Level
PL e
PFH
d
3.1 x 10
-9
/ h
2)
Mission time
20
years
Controls and indicators
Operating voltage
5 … 24
V
Operating current
1 … 100
mA
Breaking capacity max.
250
mW
Power supply LED
24
V DC
1) Values at a switching current of 50 mA without taking into account the cable lengths.
2) Applying the limit value from EN ISO 13849-1:2008, section 4.5.2 (MTTF
d
= max. 100 years), the employers' liability insurance
association certifies a PFH
d
of max. 2.47 x 10
-8
.