16 inspection and service, Inspection and service – EUCHNER MGB-L2-xxxAPx-xxx User Manual
Page 36
36
Operating Instructions MGB-L1...AR.-... / MGB-L2...AR.-... and MGB-L1...AP.-... / MGB-L2...AP.-...
16 Inspection and service
Warning!
Loss of the safety function because of damage to the system.
In case of damage, the affected module must be replaced completely.
Only accessories or spare parts that can be ordered from EUCHNER may be
replaced.
Regular inspection of the following is necessary to ensure trouble-free long-term
operation:
Ì
Check the switching function (see section 11.3 Electrical function test, page
30)
Ì
Check the secure fastening of the devices and the connections
Ì
Check for soiling
No servicing is required, repairs to the device are only allowed to be made by the
manufacturer.
Note:
The year of manufacture can be seen in the lower right corner of the rating plate.