14 Troubleshooting and assistance

14.1 Fault reset

Proceed as follows:
1. Switch the operating voltage off at the locking module for min. 3 seconds.

As an alternative, 24 V can be applied to the input RST for min. 3 seconds.

¨

The green LED (State) flashes quickly (approx. 5 Hz). A self-test is performed

during this time (approx. 8 s in case of AR configuration). The LED then cycli-

cally flashes three times.

2. Close safety guard and switch guard locking on.

¨

The system is in normal mode again.

14.2 Help on troubleshooting in the Internet

You will find a help file on troubleshooting under “Support” in the download area

at www.EUCHNER.de.

14.3 Help on mounting in the Internet

You will find an animation on the mounting process at www.mgb.EUCHNER.de.

15 Service