35
Operating Instructions MGB-L1...AR.-... / MGB-L2...AR.-... and MGB-L1...AP.-... / MGB-L2...AP.-...
14 Troubleshooting and assistance
14.1 Fault reset
Proceed as follows:
1. Switch the operating voltage off at the locking module for min. 3 seconds.
As an alternative, 24 V can be applied to the input RST for min. 3 seconds.
¨
The green LED (State) flashes quickly (approx. 5 Hz). A self-test is performed
during this time (approx. 8 s in case of AR configuration). The LED then cycli-
cally flashes three times.
2. Close safety guard and switch guard locking on.
¨
The system is in normal mode again.
14.2 Help on troubleshooting in the Internet
You will find a help file on troubleshooting under “Support” in the download area
at www.EUCHNER.de.
14.3 Help on mounting in the Internet
You will find an animation on the mounting process at www.mgb.EUCHNER.de.