EUCHNER MGB-L2-xxxAPx-xxx User Manual
Page 16
16
Operating Instructions MGB-L1...AR.-... / MGB-L2...AR.-... and MGB-L1...AP.-... / MGB-L2...AP.-...
CLOSED
OPEN
1
3
2
1
Press door handle up.
2
Unscrew locking pins
3
Push cover aside.
Figure 9: Changing actuating direction, step 1
Figure 10: Changing actuating direction, steps 2 and 3
8 Changing actuating direction (here: from right to left)
Important:
It is only possible to make this change when the bolt tongue is not extended and
an escape release is not yet mounted.
As supplied, the handle module is set either for doors hinged on the right or for
doors hinged on the left.
Based on the example of a handle module for doors hinged on the right this means:
Ì
The safety guard opens by pressing down the door handle.
Ì
The system is mounted the other way up, as it were, for doors hinged on the
left. In other words, the safety guard opens by pressing up the door handle
(see Figure 9). For this reason the actuating direction of the door handle must
be changed (see Figures 9 - 14).
(similarly on handle modules for doors hinged on the left)
4
5
4
Lift the locking pin on the door handle using a screwdriver
and hold it in this position.
5
Turn door handle to the right.
7
6
b
8
a
4 mm
6
Only if using an escape release: using the hexagon head
screw, turn the joint counterclockwise from position (a) to
position (b).
7
Close cover.
8
Screw in locking pins and tighten to 2 Nm.