Tambourine 100 Power Supply
MAN-TAM-100IG (Ver. 1.101)
5
1.1. Warnings
To avoid electric arcing and hazards to personnel and electrical contacts, never
connect/disconnect the Tambourine 100 power supply while the power source
is on.
Disconnect the Tambourine 100 power supply from all voltage sources before it
is opened for servicing.
The Tambourine 100 power supply contains grounding conduits for electric
current protection. Any disruption to these conduits may cause the instrument
to become hot (live) and dangerous.
When the Tambourine 100 is connected directly to the Mains, VN- must not be
connected to the PE!
After shutting off the power and removing the power source from your
equipment, wait as described in the tables below, before touching or
disconnecting parts of the equipment that are normally loaded with electrical
charges (such as wires or contacts). It is recommended to measure the electrical
contact points with a DVM before touching the equipment.
Function
Ref.
Results
1
Discharge time with no load
VP+, VN-
3 mins
2
Discharge time with more than 20A load
VP+, VN-
1 min
Table 1: Safe Discharge Time
1.2. Cautions
The Tambourine 100 power supply contains hot surfaces and electrically charged
components during operation.
The maximum AC/DC power supply connected to the instrument must comply
with the parameters outlined in this guide.
Before switching on the Tambourine 100 power supply, verify that all safety
precautions have been observed and that the installation procedures in this
manual have been followed.